6.1 Release
Note
Open issues: (Generated on Wednesday, 11 October 2017: 15:41:00)
Key |
Summary |
Component/s |
Release Note |
IDE-14793 |
More than 16 Monitor points can be set. |
Advanced Debug Manager (ADM) |
In Current Consumption View, the max count of monitor point is 16.
Monitor points can be added over 16, but it is set only 16 points when
starting measurement, and the points which failed to set are disabled. Please
set enable/disable points, so that the expected points are set. |
IDE-15182 |
Monitor point can be set, other than E2. |
Application |
Monitor points can be set by 'Toggle Monitor Point' menu. But the
monitor point only works with E2 emulator. |
IDE-15894 |
Cannot delete Hew project on e2s 6.0 |
Application |
HEW projects cannot be removed from the workspace after importing a
HEW project. |
IDE-3389 |
Source Addresses: mutliple debug contexts
with same-named source file |
Application |
When debugging files with the same name show source addresses even
though it may not be correct for the file in question. The full file path is
not considered just the filename and current debug context. This can lead to
e2 studio showing addresses unnecessarily. |
IDE-3950 |
breakpoints cannot be unset within the editor when code is #ifdef out |
Application |
Breakpoints cannot be unset on editor if the codes are out of #ifdef close. |
IDE-4438 |
RL78 Assembler/Disassembler does not treat instruction code of DIVWU
correctly |
Application |
The e2 studio debugger (GDB) does not deal correctly with this RL78
mnemonic. It uses the wrong instruction code: |
IDE-4492 |
The Module View of e2studio does not display any information when an
executable which includes debug information was downloaded to the target. |
Application |
The Module View of e2 studio does not display any information when an
executable which includes debug information was downloaded to the target. |
IDE-7298 |
dialog should be re-sizable as font size |
Application |
When font size is changed as magnified, some user interface controls
are hidden. |
IDE-7419 |
RL78 on-chip debugging and reserved areas problem |
Application |
In older versions of e2 studio the RL78 debugger would protect OCD
memory areas for the E1 emulator. |
IDE-7498 |
Multi-byte chars should be denied as Build-Debug configuration name |
Application |
Multi-byte characters can cause a compilation failure when used as a
build configuration name in e2 studio. |
IDE-8099 |
Mouse-ing over the breakpoint Types causes
e2 studio to crash |
Application |
When using Ubuntu using Unity there is an issue which causes e2 studio
to crash. When hovering over the breakpoint types the e2 studio application
crashes. |
IDE-8450 |
empty view on minimize and restore (Variables, Expression, IO
Register, etc) |
Application |
When minimizing a view such as Expressions, Registers or IO Registers
and the restoring the view it can appear blank. |
IDE-8627 |
System Explorer launch breaking E2 |
Application |
On some systems you may encounter an error when launching the system
explorer from the Project Explorer context menu. If using this causes e2
studio to freeze or context menus to stop displaying you should terminate the
e2 studio process. |
IDE-8651 |
Can't update e2studio to V4.3 |
Application |
If during the update process you see a message similar to: |
IDE-9507 |
Setting breakpoint in function referenced in expression view causes
debugger to hang |
Application |
Setting a breakpoint to a function which is referenced from an
expression in the expression view causes the debugger to hang when execution
is resumed. When this happens e2 studio must be restarted to resume normal
operation. |
IDE-8711 |
Timing to show 'Unable to modify eventpoins'
message is strange. |
Application, Eventpoints plugin |
When the timer start/stop events are set in Editor view of RX, the
message to notify the limit number may not be displayed. |
IDE-16744 |
Certificate approval screen can cause e2 studio to appear to lock |
Application, Smart Manual Discovery |
The certificate approval screen which appears during automatic smart
manual installation can cause e2 studio to appear to lock. |
IDE-14552 |
[PG/Builder] GCC plugins - assembler files not recognized by CDT |
ARM GCC Plugins, RL78 GCC build plugin, RX GCC build plugin |
When using GCC toolchains if there is a mixture of “.s” and “.S”
assembly source files some files will not be built. Please rename all
assembly source file extensions to be the same case. |
IDE-15192 |
Switching between Executable and Library project types |
ARM GCC Plugins, RL78 GCC build plugin, RX GCC build plugin |
Switching from a library project output to an executable on the GCC
build artefact page does not restore the correct extension. This must then be
added manually. |
IDE-15640 |
Libgen needs to be rebuilt when associated options change |
ARM GCC Plugins, RL78 GCC build plugin, RX GCC build plugin |
When using the GCC
ARM tools for RZ. If you are using project built options and modify the
related build settings for libgen the library is
not automatically rebuilt. |
IDE-16970 |
Section data should not be displayed with importing old project. |
CCRL Build plugin |
* CC-RL project |
IDE-16707 |
Resource Custom Build Steps do not work for Renesas Toolchains |
CCRL Build plugin, CCRX Build plugin |
* CC-RX project and CC-RL project |
IDE-17071 |
[Custom Tool] Custom phase was executed after the compile phase ->
Build failed |
CCRL Build plugin, CCRX Build plugin |
* CC-RX project and CC-RL project |
IDE-2762 |
CODAN errors for assembly code in C file |
CCRL Build plugin, CCRX Build plugin |
CODAN does not recognize compiler-dependent expressions as well as
assembly code expressions. |
IDE-15085 |
Disable CG button although it is checked when push [Back] and [Next] |
CCRX Build plugin |
When creating a project, the following procedure will result in
unexpected results. |
IDE-16801 |
[CC-RX] Some setting options is not updated correctly with user
configuration and multiple configurations |
CCRX Build plugin |
* CC-RX project |
IDE-1982 |
Renesas : Converter phase gets invoked for external linker subcommand
option |
CCRX Build plugin |
For Renesas CCRX the Converter phase gets invoked even when using the
external linker subcommand option. This should not happen. |
IDE-3928 |
Editor and Compiler default input character code should match |
CCRX Build plugin |
By default the e2 studio editor character code is set to UTF-8. This
means it is possible to enter characters that are then not supported by
default by the CCRX toolchain. |
IDE-4515 |
Unable to build project with produces input longer than 8191
characters |
CCRX Build plugin |
When building projects with CCRX that are in deep directory structures
it is possible to experience build issues. e2 studio
is unable to build projects which create command lines greater than 8191
characters. |
IDE-5171 |
Preinclude file is not analyzed
for preprocess statement in editor |
CCRX Build plugin |
As editor behavior, files included in the
Pre-include build options look like unrecognized as pre-processor statements.
However, those files will be actually included in the build process. |
IDE-7508 |
CCRX: Warning dialog shows many times on Turkish OS when input 'i' key for e2 studio location |
CCRX Build plugin |
Problem: |
IDE-17194 |
Options not being set properly |
CCRX to GCC Converter |
When using the CCRX to GCC conversion tool you may experience some
problems with the setup of “Select library” and “Include File Directories”. If you experience this problem please copy the settings from the
source project to the converted project. |
IDE-17215 |
Unable to debug converted CCRX to GCC RX project |
CCRX to GCC Converter |
When converting from CCRX to RX GCC the file dbsct.c
causes errors after conversion. To work around this issue visit the device page in the build settings
and tick the check boxes to re-generate the files provided by the project
generator. This workaround will work for 6.0 projects only. For 5.4 or earlier
you will have to manually correct the issue. |
IDE-6350 |
[Multiple Configuration]: NullPointerException
with custom configuration |
CDT |
NullPointerException is observed when adding a custom
configuration and selecting the same configuration within the ‘Multiple
Configuration…' selection at the same time. |
IDE-6529 |
Disassembly view is empty after restart |
CDT |
After restart on occasion the disassembly window can be empty.
Refreshing the window or stepping works around the problem. |
IDE-7403 |
Indexer setting not saved. |
CDT |
The setting 'Use a fixed build configuration' in the dialog,
Properties->C/C++ General->Indexer is not saved when the user checks
it. |
IDE-7423 |
Disassembly view does not always update on initial opening |
CDT |
In some cases the disassembly view does not refresh correctly on
suspend. When this problem happens the refresh operation does not fix the
problem. To restore the functionality close and re-open the view. |
IDE-16062 |
Code Generator not registered when installed in a seperate
folder |
CodeGenerator plugin |
When e2 studio is installed in multiple locations on the user’s
machine and they are same version, the Code Generator does not work. |
IDE-15565 |
[IT] Mouse hover in Current Consumption view appears in wrong monitor
for dual-monitor setup |
Consumption Current |
When running e2 studio with a dual-monitor, and if e2studio is running
on second monitor, the popup window for Current Consumption will be displayed
on first monitor. |
IDE-16186 |
[UT] Mouse hover in Current Consumption view appears in wrong monitor
for dual-monitor setup |
Consumption Current |
When running e2 studio with a dual-monitor, and if e2studio is running
on second monitor, the popup window for Current Consumption will be displayed
on first monitor. |
IDE-16371 |
[DevTest] Issues in save current consumption
dialog |
Consumption Current |
When using Current Consumption View and saving data to CSV file, if
the specified file is already exist, no warning is displayed. And also, if
the location is not arrowed to store a file, no error is displayed and file
is not created. |
IDE-17036 |
Start measurement of current consumption error when have more than one
project contain monitor point |
Consumption Current |
When using Measuring Current Consumption View with the workspace which
has several projects, if monitor points are set at the project which is not
debugging, start measurement will show the error. In this case, please
disable the monitor points which are not for the debugging project. |
IDE-17089 |
Monitor point can't be set if NOP is not inserted at the top of the
line. |
Consumption Current |
When using monitor point insertion with CCRL 1.05 for Current Consumption
View, if nop is not inserted at the top address of
the line, setting monitor point will fail. In this case, please insert NOP() in the source code manually. |
IDE-17111 |
Measurement feature is disabled if start debug while Current
Consumption view closed |
Consumption Current |
When using Current Consumption View with E2 emulator, if the view is
closed when connecting debugger, the enable button may be disabled. In this
case, please disconnect and reconnect again with the view open. |
IDE-5668 |
Coverage: IECUBE shows 'branch' for lines that should be 'covered' |
Coverage plugin |
In some cases when using the Coverage facility with the RL78 IECUBE
some lines are shown as 'branch' or partial coverage when they should be 100%
covered. |
IDE-6657 |
Failed to show coverage for the copied or moved workspace. |
Coverage plugin |
If the workspace is copied or moved from the original folder, coverage
information may not be displayed. |
IDE-17132 |
Imports or Exports CS+ RTOS project |
CubeSuite+ importer/exporter |
RTOS (CC-RX) projects of CS+ cannot be imported into e2 studio. Also, RTOS (CC-RX) project of e2 studio cannot be exported to CS+. |
IDE-17150 |
Individual compiler option (-outcode) is not
correct with importing CS+ project |
CubeSuite+ importer/exporter |
When local compiler options are set on files in CS+ and then imported
into e2 studio there are cases where the options are not restored correctly. e.g. -outcode setting. |
IDE-10423 |
Automatic data flash erase on RL78 device during the debug session
start via E1 |
Debug Configuration |
Erase flash on start-up option on RL78 should be executed once. |
IDE-1778 |
More that 4 'Internal Flash Memory
Overwrite' blocks being allowed. |
Debug Configuration |
When setting the 'Internal Flash Memory Overwrite' debug option, it is
possible to exceed the maximum number of non-continuous memory blocks
supported. No warning is given if this limit is exceeded. |
IDE-6408 |
(RX) Selecting user boot mode always show the message. |
Debug Configuration |
When User boot mode is selected at the setting for Mode pin in CPU
Operating Mode, the warning for USB boot program is displayed even if the
device does not have USB boot program. |
IDE-6493 |
Setting invalid value is allowed in E1 debugger for RX |
Debug Configuration |
For the debug configuration of RX, 'Operating Frequency [MHz]' is not
validated and therefore wrong values can be accepted with no warnings. Please
confirm if the appropriate value is configured as operating frequency. |
IDE-8438 |
'Internal Flash Memory Overwrite' option for RX E1 needs the number
limitation. |
Debug Configuration |
If more than 16 non-adjacent items are selected from the
"Internal Flash Memory Overwrite" dialog, only the first items will
be valid. Others will be discarded. |
IDE-17007 |
[RX with EZ] Cycle step on Performance analysis cannot be displayed
with the unit [ns]. |
Debug Configuration RX |
When using RX via EZ emulator, the performance timer value will be
only displayed as count which is counted as ICLK. |
IDE-17008 |
-uExtFlashFile is not specified to the
command line of GDB server unless Debug configuration is not opened once. |
Debug Configuration RX |
When downloading external flash with RX, if debug configuration is not
opened once after starting up e2 studio, downloading will fail. In this case
please open the debug configuration for the the
selected debug hardware. |
IDE-4876 |
Rx, In flash write mode, debugger features should be disabled |
Debug Configuration, GDB server RX |
When debugging with RX, if the settings are in flash write mode, the
debugger features are not available. If the ID code is changed or the
communication I/F is FINE, reading memory will fail after download finished.
Please disconnect from emulator and pull USB cable out in this case. |
IDE-16697 |
Renesas Debug Virtual Console causes hang issue when using Multiple
Debug session |
Debug Console plugin |
When connecting two debug session and using Renesas Debug Virtual
Console, please note the following case. |
IDE-16640 |
Add ability to load symbol files at specified location and offset on
reload |
Debug Launch |
Currently there is no way to load symbol files at specified location
and offset when debugging a Linux target for RZ/G. The workaround is to use the GDB console window to load the symbol
file using the GDB protocol. |
IDE-16065 |
Symbols not available in source for RZ/G Debug session |
Debugger |
The source address column does not have addresses added to it when
debugging with RZ/G. |
IDE-9101 |
Cannot launch debug session when breakpoint cannot be set |
Debugger |
If GDB is unable to set a breakpoint during the launch then the whole
launch will be aborted. Removing the breakpoint(s) will allow the launch to
complete successfully. |
IDE-16614 |
[IECUBE] standalone debug should be warned with board connection |
Debugging RL |
When using IECUBE (RL78), no warning will be displayed, even if the
board is connected when the setting 'Connecting with target board' is set to
'No'. |
IDE-10108 |
Error Dialog is shown when disconnected. |
Debugging RX |
When hitting Disconnect on a running debug session (with breakpoints
in use) the debugger will error and fail to disconnect |
IDE-12844 |
Build release not working for RZ/G |
Debugging RZ, Managed Build |
The RZ/G default project will not build in the release build
configuration. |
IDE-12878 |
Enabling BSD sockets in ThreadX source code
breaks RTOS Resources View |
Debugging Synergy |
When using the Synergy editor if you enable the BSD sockets in the ThreadX source code updates to the RTOS resources view
and e2 studio debug view will no longer work correctly. |
IDE-17104 |
ITM not working correctly on Synergy S5 devices TRCLK incorrectly set |
Debugging Synergy |
Currently on Synergy S5 devices the ITM trace feature is not
supported. |
IDE-9393 |
Coresight SWV Clock setup needs improvement |
Debugging Synergy |
On Synergy devices the default "Core Clock" value for SWV
usage should be set to the same as the system clock (in Mhz).
For S7 devices (where the trace clock is halved) this should be set at half
the system clock. |
IDE-17207 |
DS5 Environment Problem |
DS-5 importer |
When a DS-5 project is imported into e2 studio the environment
variables for Path and TCInstall are copied from
the DS-5 environment. This is not correct. The way to correct this problem is to delete
both of these paths and replace them with correct values to your toolchain.
If you are unsure how to correct this please create a new project and copy
the values from this to the converted project. |
IDE-10061 |
e2Studio Installer Fails with Spaces in User Name (Windows) |
Eclipse Platform |
The e2 studio installer can fail when installing to machines where the
user name has spaces included in the name. |
IDE-9972 |
e2 studio fails to launch after Update |
Eclipse Platform, Installer |
In rare cases e2 studio may fail to launch after updating, either
using the installer or though the online update mechanism, instead displaying
a dialog "An error has occurred". |
IDE-16696 |
A warning dialog appears when re-debug project (eventpoint). |
Eventpoints plugin |
When connecting to debugger, Warning dialog for Eventpoint setting
sometimes appears and the following message is shown. |
IDE-6605 |
Eventpoints disabled when e2 studio first opened. |
Eventpoints plugin |
The enable state of eventpoints for any debug configuration is not
restored when the debug configuration is launched for the first time after e2
studio is started. |
IDE-6616 |
Data Access Event Break compare value always converted to hex |
Eventpoints plugin |
When adding a new Data Access eventpoint, the Compare value (on the
Data Access Settings tab) is always converted to hex and subsequently
displayed in hex even if the value entered does not include an 0x prefix. |
IDE-9338 |
Get correct number of HW breakpoints and eventpoints |
Eventpoints plugin |
The event count on Eventpoint View shows the total event count
including hardware break points which are set on source view as line break
points. |
IDE-2246 |
The RX simulator does not allow trigger count on data access events. |
Eventpoints plugin, GDB server RX |
The trigger count for data access event for RX simulator will be
ignored. |
IDE-16582 |
RX debugger does not show address of "#pragma section" in a
.c file. |
GDB |
RX debugger does not show address of "#pragma section" in a
.c file. |
IDE-16893 |
Cannot change gdb for RZ/G from default gdb.exe to Linaro
gdb |
GDB |
Selecting the GDB from the Linaro toolchain
will not work unless the associated Python is also installed. |
IDE-8592 |
Step return and step over does not work for RL78 after hotplug connection. |
GDB |
After connection with hotplug for RL78,
'step return' and 'step over' execution may not work. Please use a hardware
break and resume command. |
IDE-8725 |
GDB will crash when resume command or step command returns an error.. |
GDB |
If the software break points are used even if they are not allowed,
GDB will fail to debug. For example, setting software breakpionts
in trusted memory area for RXv2 core, or in CS0 area for Internal ROM
disabled extended mode will cause this. Please use hardware breakpoints in
this case. |
IDE-9090 |
Multiple breakpoints set for multiple symbol files |
GDB |
When the same symbol files are downloaded on to 2 different processes
and the User sets a source breakpoint, GDB will set the breakpoint on both
processes. |
IDE-4607 |
[BREAKPOINT] (RL78)Behavior in the case of
the error by Add Watchpoint. |
GDB server |
When sub menu "Add Watchpoint" is
performed from a Memory view, it seems to have been registered correctly in
the Breakpoints view even if there is an error condition. |
IDE-8302 |
Semihosting - printf causes
subsequent file operations to fail |
GDB server |
When using semihosting, having a printf command before file io
operations causes them to fail. |
IDE-5547 |
Trace record event for READ access with compared data acquires
information which does not match it. |
GDB Server RH850 |
To use the data
access events as trace start, trace stop or trace record for RH850 with E1
emulator, please do not use the "Compare Settings" condition for
the event. |
IDE-5780 |
rh850 BPC events do not count in the status area of the eventpoints
view |
GDB Server RH850 |
The counter of the event points in Eventpoint view will not be counted
correctly. |
IDE-12733 |
[RL78/G10 with EZ] program doesn't suspend at reset vector |
GDB server RL78 |
There is a known issue when debugging RL78/G10 with the EZ emulator.
In some condition the program doesn't suspend at reset vector. |
IDE-15236 |
Resume will fail if 'Permit Flash Programming' is set to No. |
GDB server RL78 |
If 'Permit Flash Programming' is set to No in the debug configuration
for RL78 Emulator, resume the program will fail. When debugging, please set
this option to Yes. |
IDE-2716 |
BeforePC events on IECube temporarily hardcoded
limit of 4 |
GDB server RL78 |
Before PC events on IECube temporarily hard
coded limit of 4. |
IDE-7412 |
Setting RL78 register fails |
GDB server RL78 |
When using RL78 the HL register value cannot be modified in some
circumstances. |
IDE-8503 |
RL78 SmartAnalog Memory can't be read during
execution |
GDB server RL78 |
The devices with a SmartAnalog(e.g.RL78/I1E) will not be able to memory read during
execution. |
IDE-11571 |
The result of Run-Break Timer is not indicated after program is stopped
by software breakpoint |
GDB server RL78, Performance Analysis |
When debugging RL78/SDMA1 device with E1 emulator, the result of
Run-Break Timer is not indicated after program is stopped by software
breakpoint. |
IDE-3626 |
Trace Record Eventpoints do not seem to be removed during a session |
GDB server RL78, Trace plugin |
Snapshot trace - adding IO register eventpoints increases the data
shown in the trace view, but as they were removed there was no change in the
data shown. |
IDE-12094 |
Coverage feature of E20 can't show the data over banks. |
GDB server RX |
E20 emulator has the coverage 4 * 4MB blocks for RXv2 core devices.
This block is aligned with 4MB boundary. If the program executed from the
block to the next block without branch, the coverage from the top of next
block to the first branch will not be recorded. |
IDE-4982 |
[RX] The debugger works same as 'Equals' even if I select 'Not Equals'
in 'Comparison:' of 'Data Access Settings'. (only when 0x0 is specified to
Mask Value) |
GDB server RX |
When a data access event for RX is set with the data mask value as 0,
the comparison will be treated as "Equals" and the data mask value
will be treated as 0xFFFFFFFF. |
IDE-6701 |
Step Immediate targets improvement |
GDB server RX |
For RX devices, when 'step' command is invoked for WAIT instruction,
GDB might report an error. |
IDE-8415 |
Connection with 'Internal Flash Memory Overwrite' may fail. |
GDB server RX |
Selecting more than 16 non-adjacent items from the "Internal
Flash Memory Overwrite" dialog will cause the connection to an RX device
to fail. |
IDE-8579 |
Execution time for the last function may not be displayed in Profile
View. |
GDB server RX |
In Profile view, execution time for each function is calculated for
the function which is returned out. If the execution stopped at the middle of
the function, execution time of the function may not be added. |
IDE-874 |
[BREAKPOINT ISSUE]: Execution Address Eventpoints with trigger count
do not work with Breakpoints on Segger RX |
GDB server RX |
Execution Address Eventpoints with trigger count do not work with
Breakpoints on Segger RX. |
IDE-9045 |
Connection Exception with RX64M GR-KAEDE Board using last known
connection |
GDB server RX |
Project based variables in the debug configuration are not evaluated
correctly at launch and the launch then fails. |
IDE-5770 |
Memory View for RX Little Endian shows IO endian reversed |
GDB server RX, IO view plugin |
RX targets and IO registers greater than 1 byte. |
IDE-7524 |
RZ/T1 Reload doesn't work on RAM_BOOT project |
GDB Server RZ |
For RAM based RZ-T1 projects a redownload of
code will trigger a reset that erases the RAM making further debugger
operation impossible. The workaround is to instead disconnect and then
reconnect. |
IDE-12571 |
Not possible to ALeRASE ID to erase device
when ID byte is programmed under e2studio |
GDB Server Synergy |
Currently the use of the special ALeRASE ID
code unlock does not work correctly with e2studio. The device will remain
locked. The workaround is to use the ALeRASE code
in the RFP tool instead. |
IDE-8461 |
NO TRACE ON S3A7 |
GDB Server Synergy |
On Synergy S3-based devices the trace can sometimes fail with 0
records. |
IDE-9057 |
[Trace view] The Filter + Find feature seems not work correctly with
Synergy project |
GDB Server Synergy |
Trace find and filter functionality is currently not supported for
ARM-based devices |
IDE-17142 |
KPIT RX project for HEW cannot be imported. |
HEW Project Converter |
The HEW project converter cannot currently convert a HEW RX KPIT GCC
project to e2 studio. This will be fixed in a subsequent release. |
IDE-17152 |
Linkage order is not correct with importing HEW project |
HEW Project Converter |
The HEW Project Converter when used for CCRX can create a different
linkage order in the imported project. This has been reproduced when using a project from HEW V4.09.01 and
CCRX Toolchain V1.02.01 when linkage order is switched on |
IDE-1808 |
HI: Include paths are duplicated |
HEW Project Converter |
Import a HEW RX project in e2studio using the HEW project importer. |
IDE-7277 |
[IAR][RL78] Linker extra options were not imported |
IAR plugins |
In some cases the IAR project importer does not perfectly import all
set build options. |
IDE-16294 |
[Smart Manual] Wrong device name when using "Show in Smart Manual
view" button from IO Register view |
IO view plugin, Smart Manual plugin |
Smart Manual View treats the selected project in the project explorer
as the target project. |
IDE-16878 |
Download fails for CC-RX Big-endian projects. |
Loadmodule Converter |
When data section is set as code section and it is not 4 bytes alignments,
it fails to download with CC-RX big-endian project. |
IDE-9309 |
Cannot perform source level debugging for the section that inside
another section |
Loadmodule Converter |
Problem
(condition): |
IDE-16117 |
"Build Automatically" does not rebuild after
"Clean" CCRX project |
Managed Build |
Even if you specify "Build automatically", Build will not
perform automatically. |
IDE-1616 |
The options of a Build Configuration were not correct after specifying
“Multiple Configurations...” functionality. |
Managed Build |
The options of a Build Configuration were not correct after specifying
Multiple Configurations... functionality. |
IDE-16830 |
The "Project Upgrade Required" pop-up does not appear on
subsequent imports of the same project |
Managed Build |
If a legacy project is imported, deleted and then imported again, in
the same workbench session, the "Project Upgrade Required" pop-up
does not appear on subsequent imports. Right clicking on the project and selecting “Upgrade Legacy projects”
should upgrade the project in this case. |
IDE-5897 |
Build error when project path has Chinese/Japanese text. |
Managed Build |
When operating e2 studio in a path that has Chinese or Japanese in the
path names you may experience problems invoking the application. Please
rename the directory with alphanumeric characters. |
IDE-17180 |
OpenOCD launch file generated by mbed cannot be loaded
into configuration |
mbed Exporter |
Due to changes within the mbed system the
currently exported projects do not contain launch configurations that will
work in e2 studio. In this situation the launch configuration will need to be created
manually. |
IDE-12725 |
Symbol tab of Memory Usage view displays incorrectly information of
global variables |
Memory Usage plugin |
Global variable may be shown mistake the size at Symbol tab on Memory
Usage. |
IDE-16491 |
Add "Open build option page" feature for Memory usage plugin |
Memory Usage plugin |
Button "Open Map file output page" dialog" and
"Open Section page" dialog will open "Properties" page.
Please jump to "Settings" tab by selecting "C/C++
Build->Settings". |
IDE-16780 |
Improve error messages for GCC library projects |
Memory Usage plugin |
GCC library project (RL, RX, and RZ) does not have .lbp file. "Can't open library list file."
message will be displayed in Memory Usage view with GCC library projects. |
IDE-4869 |
Memory view always opened on launch of debug session |
Memory View plugin |
The "Memory" view always opened on launch of a debug
session. It should not be re-opened on launch if it has been closed in the
previous debug session. |
IDE-8875 |
GDB Server will crash when Start address is larger than End address in
Find/Replace/Fill Memory dialog |
Memory View plugin |
e2 studio can crash when the memory view Find/Replace/Fill feature has a
start address larger than the end address. |
IDE-9494 |
Memory view address caption should match to endianess |
Memory View plugin |
Users may misunderstand the data order in the memory view due to the
address column heading. |
IDE-16103 |
[IT] [Misra-C Checker plug-in] Violations
list still display when user changes language of source file |
MISRA-C plugin |
Violations list still display when user changes language of source
file from C89 to C99. |
IDE-16884 |
MISRA-C messages are not shown on Problem view and tool-chip on Editor
by changing toolchain version. |
MISRA-C plugin |
It cannot check
MISRA-C rule for a resource is opened with unsupported toolchain (for MISRA-C
plugin). Even the project is changed into supported toolchain, this resource
cannot be check MISRA-C with editing and saving. |
IDE-5637 |
(RH850) Disassembly result of PE1 is different from the result of PE2. |
Multicore Debugging RH850 |
For RH850 multicore devices, disassembly result may be different from
the expected. In this case, please refresh the view after changing the debug
context to the other PE. |
IDE-9685 |
Performance result is sometimes not displayed if "Pin to Debug
Context" is selected |
Performance Analysis |
When "Pin to Debug Context" is selected, Performance
Analysis view, Profile view, Trace view, Coverage view could be displayed
incorrectly sometimes. |
IDE-8303 |
An internal error for “Acquiring Profile Result” may be shown when the
program stops/starts |
Profile plugin |
An internal error for "Acquiring Profile Result" may be
shown when the program stops/starts |
IDE-4189 |
Not able to build project which is having more than 98 characters in
its project name. |
Project Generation Core |
It is not possible to build project which has more than 98 characters
in its project name. |
IDE-9032 |
"Rename & Import Existing C/C++ Project into Workspace"
option allows the use of illegal characters in the new project name |
Project Generation Core |
Rename and Import existing C/C++ project does not have the same
restrictions as new project wizard. |
IDE-8555 |
Unable to create a synergy project in Turkish Windows 8.1 |
Project Generation Core, Renesas Synergy |
When using Turkish Windows with Synergy you may experience problems
creating a project. |
IDE-16925 |
Cannot debug for RZ/T device using the GDB simulator |
Project Generator GCC RZ |
Cannot debug for RZ/T device using the GDB simulator. The GDB Simulator only supports ARMv6 instruction set. |
IDE-6566 |
RH850 multicore realtime expression update
does not work |
Real-time Watch |
In some situations the RH850 multicore realtime
expression update does not work. |
IDE-7333 |
1ms refresh interval in expressions using RX Simulator does not work |
Real-time Watch |
When using the RX Simulator with real-time expressions if you use 1ms
real-time interval the expression view goes blank. On suspend, e2 studio
appears to hang while messages are processed. |
IDE-11337 |
Copy and paste support in the threads page of the Synergy editor needs
e2Studio RESTART to work correctly |
Renesas Synergy |
In certain situations it is possible for the copy/paste actions to
stop working in the Synergy editor, threads page. If this happens please
close the Synergy editor and re-open it. Copy and paste should then work
correctly. |
IDE-11651 |
Headless build with GCC compiler issue |
Renesas Synergy |
When using the headless build functionality with Synergy the build
will not execute unless the licence file for the SSP is defined correctly
within the system environment. This is the current specification for headless
build. |
IDE-8980 |
Headless Build error with Synergy project |
Renesas Synergy |
When using the eclipsec.exe tool and running headless builds it is
possible to see an error created as seen below: |
IDE-9612 |
[Eventpoint] Red X icon is shown when setting Eventpoint for Synergy
project |
Renesas Synergy |
On Synergy devices, repeated setting of Trace Start and Stop
eventpoints can lead to a situation where the eventpoints fail to set. |
IDE-10147 |
Switching Board(not save) make project settings changing unexpectedly |
Renesas Synergy, Synergy Editor |
When using the Synergy configurator if the device is changed on the
BSP tab the build options are now modified. |
IDE-8726 |
Exception was thrown when specify synergy license file by place-holder |
Renesas Synergy, Synergy Preferences |
When using a placeholder in the Synergy license dialog it throws an
exception. Please use a full path to the file. |
IDE-17083 |
Synchronized StepOver / StepReturn
cannot be done with RH 850's multi core. |
RH850 Debugging |
About step Over and StepReturn in
synchronous mode of RH850 |
IDE-16048 |
The behavior of step-return (with
breakpoint) is strange on RL78/G10 |
RL78 Debugging |
On RL78/G10 devices, setting a breakpoint at main can cause step
return to fail. The workaround is to uncheck this option on the Startup tab of the Debug Launch Configuration. |
IDE-9533 |
Fail safe break message not clear on RL78 IECUBE |
RL78 Debugging |
When the failsafe break is configured to "Stop on read from
uninitialized RAM" on the RL78 IECUBE the break occurs but the cause is
not clear. |
IDE-16886 |
Missing compiler option "-mg14" for RL78/G1H device group |
RL78 GCC build plugin |
Missing compiler option "-mg14" for RL78/G1H device group |
IDE-9554 |
[Expression] RL78/G10: Global variable and local variable show
incorrect data |
RL78 GCC build plugin |
For RL78/G10 devices there can be issues where global variables and
local variables are showing incorrect data. |
IDE-16074 |
Project build fail with GNURL78v1103 and GNURXv1202 Toolchain |
RL78 GCC build plugin, RX GCC build plugin |
The latest GCC build plugins have support for the latest Renesas GCC
toolchains. However these means the plugins support some default options that
are not supported by older legacy tools. |
IDE-16386 |
Smart Manual does not auto-install database for the secondary project |
Smart Manual Discovery |
Smart Manuals will only install automatically for the 1st project
created or imported during any e2 studio session. Manuals for other projects
will install the next time e2 studio is run. |
IDE-9873 |
"Show in Smart Manual view" button does not work correctly |
Smart Manual plugin |
"Show in Smart Manual view" button does not work correctly
when the active project does not contain file which showing on editor. |
IDE-14337 |
Stack Analysis view does not update when artifact name is changed |
Stack Analysis View |
When Stack Analysis view is showing a stack tree, if turn off
"Outputs a stack use information file" option in Tool Settings
-> Linker -> Miscellaneous and rebuild the project, Stack Analysis view
will remain unchanged. |
IDE-16807 |
Cannot search symbol by code size with GCC projects |
Stack Analysis View |
For GCC projects (RX/RL78), code size of symbols in stack tree is not
available, searching a symbol by its code size will not work. |
IDE-8165 |
The stack size of GCC-RL is incorrect for a few devices |
TargetInformationTool |
For the devices: |
IDE-12609 |
Trace view cannot be scrolled up |
Trace plugin |
Trace view supports
"find" trace record feature. If found record is out of the list of
trace records be showing in Trace view, then Trace view will jump to shown
records around found item but in this case scrolling trace view up will not
work. |
IDE-11383 |
Visual Expression Export for RL78 (or other platforms) |
Visual Expressions plugin |
Visual Expressions data is saved to the workspace not the project. |
IDE-16926 |
Real-time update does not work when debugging multiple projects while
one is suspended |
Visual Expressions plugin |
When debugging more than one project simultaneously Realtime Update will not work when any project is
suspended. |