List generated on 04/10/2018
13:54:14.
Open Tickets Requiring Inclusion in Release Note:
Key |
Summary |
Component/s |
Release
note |
IDE-23373
|
Run
commands behaviour after a reset from the UI is not consistent |
Application
|
The
GDB run commands which are setup on the debug configuration are not
consistently applied. After
the connection process they work correctly however on subsequent debugger
reset operations the result is inconsistent. |
IDE-23127
|
Software
breakpoint set at main causes error in start/stop functions |
Application
|
When
debugging RX, if start/stop function feature is enabled, please remove or
disable all software breakpoints before the first execution. After executing
once, it can be enabled. |
IDE-22718
|
e2
studio fails to restart initially after updating from 7.0.x to 7.1.x |
Application
|
When
using the check for updates feature within e2 studio and updating from 7.0.x
to 7.1.x the initial restart after the update fails. An error message is
displayed. Subsequent launches of e2 studio work without issue. This
is caused by the update to Java. |
IDE-21904
|
Cannot
open any new perspective after resetting "Resource" perspective |
Application
|
If
you reset the "Resource" perspective, you will not be able to open
any new perspectives until you restart e² studio. |
IDE-20843
|
Subversion
Local Checkout - Database permanently locked |
Application
|
When
using the Subversion Eclipse plugin (Subversive) along with an external
Subversion client some problems can be caused. Please
use either the internal or external client. |
IDE-20542
|
e2s
hangs when debugging a project and this project was closed |
Application
|
e2
studio can hang when debugging a project and the project being debugged is
closed. Please terminate the debugger before closing the Workbench. |
IDE-18746
|
When
changing the device in the Synergy configurator the project is not updated in
the Smart Browser |
Application
|
Changing
the device in the Synergy editor does not refresh the selected device in the
Smart Browser plugin. Manually refreshing the Smart Browser plugin does not
fix this issue. |
IDE-15894
|
Cannot
delete Hew project on e2s 6.0 |
Application
|
HEW
projects cannot be removed from the workspace after importing a HEW project. |
IDE-8651
|
Not
possible to update e2 studio |
Application
|
If
during the update process you see a message like: |
IDE-8627
|
System
Explorer launch breaking E2 |
Application
|
On
some systems you may encounter an error when launching the system explorer
from the Project Explorer context menu. If using this causes e2 studio to
freeze or context menus to stop displaying you should terminate the e2 studio
process. |
IDE-8450
|
Empty
view on minimize and restore (Variables, Expression, IO Register, etc) |
Application
|
When
minimizing a view such as Expressions, Registers or IO Registers and the
restoring the view it can appear blank. |
IDE-8099
|
Cursor
hovering over the breakpoint Types causes e2 studio to crash |
Application
|
When
using Ubuntu using Unity there is an issue which causes e2 studio to crash.
When hovering over the breakpoint types the e2 studio application crashes. |
IDE-7498
|
Multi-byte
chars should be denied as Build-Debug configuration name |
Application
|
Multi-byte
characters can cause a compilation failure when used as a build configuration
name in e2 studio. |
IDE-7419
|
RL78
on-chip debugging and reserved areas problem |
Application
|
In
older versions of e2 studio the RL78 debugger would protect OCD memory areas
for the E1 emulator. |
IDE-7298
|
Dialog
should be re-sizable when comparing to font size |
Application
|
When
font size is changed as magnified, some user interface controls are hidden. |
IDE-4492
|
The
Module View of e2studio does not display any information when an executable
which includes debug information was downloaded to the target. |
Application
|
The
Module View of e2 studio does not display any information when an executable
which includes debug information was downloaded to the target. |
IDE-3950
|
breakpoints
cannot be unset within the editor when code is #ifdef out |
Application
|
Breakpoints
cannot be unset on editor if the codes are out of #ifdef close. |
IDE-3389
|
Source
Addresses: multiple debug contexts with same-named source file |
Application
|
When
debugging files with the same name show source addresses even though it may
not be correct for the file in question. The full file path is not considered
just the filename and current debug context. This can lead to e2 studio
showing addresses unnecessarily. |
IDE-18242
|
'Launch
in debug mode' button on the top left of the window will kill the current
process forcedly. |
Application,
CDT, Debug Launch |
When
pressing the launch button on the launch bar when a debugger session is
already in operation there is no warning message displayed. The current
debugger session is terminated. |
IDE-8711
|
Timing
to show 'Unable to modify eventpoints' message is strange. |
Application,
Eventpoints plugin |
When
the timer start/stop events are set in Editor view of RX, the message to
notify the limit number may not be displayed. |
IDE-16744
|
Certificate
approval screen can cause e2 studio to appear to lock |
Application,
Smart Manual Discovery |
The
certificate approval screen which appears during automatic smart manual
installation can cause e2 studio to appear to lock. |
IDE-20425
|
[RZ]
Project converter to fill FPU architecture option build fail |
ARM
GCC Plugins |
Due
to previous build plugin issues on conversion we add “.lib” to the build
artifact output prefix in some conditions. Unfortunately, this can cause
issues with some project types. If you experience an issue related to this please remove the “.lib” and rebuild. |
IDE-20680
|
Project
is not re-linked when the linker script is updated |
ARM
GCC Plugins, RL78 GCC build plugin, RX GCC build plugin |
When
linker script is changed for GCC compiler project and you build the project,
the build operation will not occur. |
IDE-23526
|
Default
parameter of -rom option does not need to specify with importing old project |
CCRL
Build plugin |
[CC-RL]
|
IDE-22741
|
[SIMBuild] Folder has Whitespace in name is not invoked in
build process |
CCRL
Build plugin, CCRX Build plugin |
[CC-RX]
[CC-RL] |
IDE-23670
|
-optimize=branch
is not converted correctly when importing CS+ project. |
CCRL
Build plugin, CubeSuite+ importer/exporter |
When
using the Renesas importer to import a CS+ project into e2 studio the CCRL
toolchain option “-optimize=branch” is not converted correctly. Please check
this after import. |
IDE-23664
|
-entry
option is not converted correctly when importing CS+ project. |
CCRL
Build plugin, CubeSuite+ importer/exporter |
When
using the Renesas importer to import a CS+ project into e2 studio the CCRL
toolchain option “-entry option” is not converted correctly. Please check
this after import. |
IDE-23663
|
-DEBUG_MONITOR
option is not converted correctly when importing CS+ project. |
CCRL
Build plugin, CubeSuite+ importer/exporter |
When
using the Renesas importer to import a CS+ project into e2 studio the CCRL
toolchain option “--DEBUG_MONITOR” is not converted correctly. Please check
this after import. |
IDE-23662
|
-no_warning_num option is not converted correctly when
importing CS+ project. |
CCRL
Build plugin, CubeSuite+ importer/exporter |
When
using the Renesas importer to import a CS+ project into e2 studio the CCRL
toolchain option “-no_warning_num” is not converted
correctly. Please check this after import. |
IDE-23325
|
CCRX
Build shows an error, failed to access a temporary file during build of large
projects |
CCRX
Build plugin |
When
building with the CC-RX toolchain at random the following message can be
displayed 'Failed to access a temporary file' error is thrown by build process.
This occurs more frequently on larger projects with complex include paths, or
paths with linked resources. If
this happens please repeat the build and it will work correctly. |
IDE-23204
|
[CCRX][Sim+Map] Clean is not invoked after removing Compiler /
Assembler source files |
CCRX
Build plugin |
(CC-RX)
|
IDE-16801
|
[CC-RX]
Some setting options is not updated correctly with user configuration and
multiple configurations |
CCRX
Build plugin |
*
CC-RX project |
IDE-18639
|
Incremental
build can break after renaming or copying a project |
CDT
|
After
renaming or copying a project incremental build might be broken & the
project will perform a full build every time. If this occurs
then: |
IDE-7423
|
Disassembly
view does not always update on initial opening |
CDT
|
In
some cases, the disassembly view does not refresh correctly on suspend. When
this problem happens refreshing the disassembly view does not fix the
problem. To restore the functionality close and re-open the view. |
IDE-7403
|
Indexer
setting not saved. |
CDT
|
The
setting 'Use a fixed build configuration' in the dialog, Properties->C/C++
General->Indexer is not saved when the user checks it. |
IDE-6529
|
Disassembly
view is empty after restart |
CDT
|
After
restart on occasion the disassembly window can be empty. Refreshing the
window or stepping works around the problem. |
IDE-6350
|
[Multiple
Configuration]: NullPointerException with custom
configuration |
CDT
|
NullPointerException is observed when adding a custom configuration and
selecting the same configuration within the ‘Multiple Configuration…'
selection at the same time. |
IDE-21649
|
[Breakpoint]
Invalid breakpoint warning is lost after using Move To
Line |
CDT,
Debugger |
After
a move to line operation in the debugger the source window is updated and breakpoint warning markers are removed from
view. |
IDE-22266
|
Cannot
start e2studio image due to Code Generator .Net Framework Exception |
Code
Generator plugin |
This
issue can occur when using multiple versions of e2 studio of the same
version. If e2 studio is installed in one location and then another
installation of the same version is installed on the same machine, then the
older installation is deleted or moved. |
IDE-21699
|
CodeGenerator cannot import AP3 project |
Code
Generator plugin |
'AP3
for RL78' project file cannot be imported into e2 studio project even if the
target device and toolchain are same between 'AP3 for RL78' project and e2
studio project. |
IDE-21570
|
Code
Generator does not work with project located in SVN/Git repository |
Code
Generator plugin |
Code
Generator is missing when loading the project shared to SVN/Git repository. |
IDE-16062
|
Code
Generator not registered when installed in a seperate
folder |
Code
Generator plugin |
When
e2 studio is installed in multiple locations on the user’s machine and they
are same version, the Code Generator does not work. |
IDE-20571
|
Coverage
plugin cannot work with virtual folder and linked resource |
Coverage
plugin |
The
Coverage plugin cannot display the result in the editor view by color if the C files are in a virtual folder or treated
as the linked resource files. |
IDE-18970
|
Data
coverage does not update after touching "Accumulate Results"
toolbar button |
Coverage
plugin |
Data
coverage result will not be updated if "Accumulate Results" is set
to OFF once. Please do not uncheck this option. |
IDE-5668
|
Coverage:
IECUBE shows 'branch' for lines that should be 'covered' |
Coverage
plugin |
In
some cases when using the Coverage facility with the RL78 IECUBE some lines
are shown as 'branch' or partial coverage when they should be 100% covered. |
IDE-17089
|
Monitor
point can't be set if NOP is not inserted at the top of the line. |
Current
Consumption View |
When
using monitor point insertion with CCRL 1.05 or CCRX 2.08 for the Current
Consumption View, if nop is not inserted at the top
address of the line because of the code generation or optimization, setting
monitor point will fail. In this case, please insert NOP()
in the source code manually. |
IDE-16371
|
[DevTest]
Issues in save current consumption dialog |
Current
Consumption View |
When
using Current Consumption View and saving data to CSV file, if the specified
file already exists, no warning is displayed. If the location is not
permitted to store a file, no error is displayed and
file is not created. |
IDE-16186
|
[UT]
Mouse hover in Current Consumption view appears in wrong monitor for
dual-monitor setup |
Current
Consumption View |
When
running e2 studio with a dual-monitor, and if e2studio is running on second
monitor, the popup window for Current Consumption will be displayed on first
monitor. |
IDE-15565
|
[IT]
Mouse hover in Current Consumption view appears in wrong monitor for
dual-monitor setup |
Current
Consumption View |
When
running e2 studio with a dual-monitor, and if e2studio is running on second
monitor, the popup window for Current Consumption will be displayed on first
monitor. |
IDE-10423
|
Automatic
data flash erase on RL78 device during the debug session start via E1 |
Debug
Configuration |
Erase
flash on start-up option on RL78 should be executed once. |
IDE-8438
|
'Internal
Flash Memory Overwrite' option for RX E1 needs the number limitation. |
Debug
Configuration |
If
more than 16 non-adjacent items are selected from the "Internal Flash
Memory Overwrite" dialog, only the first items will be valid. Others
will be discarded. |
IDE-6408
|
(RX)
Selecting user boot mode always show the message. |
Debug
Configuration |
When
User boot mode is selected at the setting for Mode pin in CPU Operating Mode,
the warning for USB boot program is displayed even if the device does not
have USB boot program. |
IDE-1778
|
More
than 4 'Internal Flash Memory Overwrite' blocks are allowed |
Debug
Configuration |
When
setting the 'Internal Flash Memory Overwrite' debug option, it is possible to
exceed the maximum number of non-continuous memory blocks supported. No
warning is given if this limit is exceeded. |
IDE-16874
|
Cannot
connect to RZ if "Image Only" is selected as Load Image |
Debug
Configuration ADAS, Debug Configuration RZ |
When
writing the PC register, GDB needs to know in what mode it is ARM or Thumb. |
IDE-18623
|
[RL78
G10] Strange behavior with Breakpoint at top main
on G10 hardware debug |
Debug
Configuration RL78, Project Generation Core |
In
case of using RL78, hardware breakpoint is realized by execution address
after PC. This will cause several issues: |
IDE-23669
|
[Debug
Configuration] The value of 'Supply Voltage[V]' textbox is NOT restored
correctly |
Debug
Configuration RX |
When
changing emulator for a Debug Configuration the value of "Supply
Voltage" may be reset to a default value. Please check that the value is
correct after changing emulators. |
IDE-17007
|
[RX
with EZ] Cycle step on Performance analysis cannot be displayed with the unit
[ns]. |
Debug
Configuration RX |
When
using RX via the EZ emulator, the performance timer value will be only
displayed as count which is counted as ICLK. |
IDE-4876
|
Rx,
In flash write mode, debugger features should be
disabled |
Debug
Configuration, GDB server RX |
When
debugging with RX, if the settings are in flash write mode, the debugger
features are not available. If the ID code is changed or the communication
I/F is FINE, reading memory will fail after download finished. Please
disconnect from emulator and pull USB cable out in this case. |
IDE-18606
|
E2
Studio "Console" view - "Renesas Debug Virtual Console"
issues |
Debug
Console plugin |
Renesas
Debug Virtual Console's pin status will not be restored for next opening e2
studio. Please active and pin it manually before debugging to avoid losing
data. |
IDE-23249
|
(debug
only project) no binaries found error at launched through context menu |
Debug
Launch, Debugging RH850 |
Debug
only projects work fine with Debug button (both in toolbar and config dialog)
to launch debugger. However,
"Renesas Hardware Debugging" context menu of Project Explorer
doesn't work. It emits "no binaries found" error. Please
use the debug only project feature from the toolbar button. |
IDE-23567
|
[RX]
Conversion from Big endian to Little endian does not work correctly. |
Debug
Launch, GDB RX |
When
using RX and changing a big-endian project to little endian the project no
longer works correctly. The endian setting is not changed correctly. |
IDE-21616
|
Connection
will fail if max+1 breakpoints are set. |
Debugger
|
If
setting breakpoint is failed, the breakpoint is marked as exclamation in the
editor view (or marked as un-checked in breakpoint view). In this case, if debugger
is disconnected and re-connected, connection will fail. To avoid this, please
remove the failed breakpoints before connection. |
IDE-9101
|
Cannot
launch debug session when breakpoint cannot be set |
Debugger
|
If
GDB is unable to set a breakpoint during the launch, then the whole launch
will be aborted. Removing the breakpoint(s) will allow the launch to complete
successfully. |
IDE-16048
|
The
behavior of step-return (with breakpoint) is
strange on RL78/G10 |
Debugging
RL |
On
RL78/G10 devices, setting a breakpoint at main can cause step return to fail.
The workaround is to uncheck this option on the Startup
tab of the Debug Launch Configuration. |
IDE-15101
|
Cannot
connect to EZ emulator when another debugger is connected. |
Debugging
RL |
When
using EZ emulator with RL78, if another emulator like E1 is connected to PC,
connection to EZ emulator will fail. Please don't connect another when using
EZ emulator. |
IDE-9533
|
Fail
safe break message not clear on RL78 IECUBE |
Debugging
RL |
When
the failsafe break is configured to "Stop on read from uninitialized
RAM" on the RL78 IECUBE the break occurs but the cause is not clear. |
IDE-23878
|
[RX]
lowlvl.src does not work in simulator |
Debugging
RX |
The
provided lowlvl.src for debug input/output operations
does not work with the RX Simulator. Please replace the lowlvl.src
as stated in E series emulator manual (R20UT2081) which works with simulator
as well as E1/E2/E2 Lite emulators. |
IDE-23357
|
The
reasons threads have stopped is incorrect when debug RX62N via Segger J-link
(RX) |
Debugging
RX |
When
the debugger stops execution, the reason reported in the debug view is not
correct when using the Segger J-link. The Debug View shows (Suspended:
Signal: 0:Signal 0) when it should instead show (Suspended:
Signal: SIGINT:Interupt). |
IDE-10108
|
Error
Dialog is shown when disconnected. |
Debugging
RX |
When
hitting Disconnect on a running debug session (with breakpoints in use) the debugger
will error and fail to disconnect |
IDE-8795
|
[RX6Z4]
Breakpoint filter is not restored when reconnecting debugger |
Debugging
RX |
If
you perform Disconnect-> Connect operation on the debugger, the Breakpoint
Filter setting will not be restored correctly. |
IDE-23921
|
Register
View shows wrong value |
Debugging
RZ |
When
debugging RZ/A1, A2 with J-Link, an incorrect value is displayed in the CPSR
register of Register view. |
IDE-21737
|
RZ/A
serial launch with Linux target doesn't show console output from target |
Debugging
RZ Linux |
With
ethernet based connections for Linux target debugging, e2 studio starts GDB
server and captures output of the process. With Linux target, serial
connection GDB server is started but the console output is not captured. |
IDE-21601
|
RZ/A
serial COM port doesn't work if port number is greater than 9 |
Debugging
RZ Linux |
RZ/A
serial COM port does not work if the port number is greater than 9. |
IDE-12878
|
Enabling
BSD sockets in ThreadX source code breaks RTOS
Resources View |
Debugging
Synergy |
When
using the Synergy editor if you enable the BSD sockets in the ThreadX source code updates to the RTOS resources view
and e2 studio debug view will no longer work correctly. |
IDE-9393
|
Coresight SWV Clock setup needs improvement |
Debugging
Synergy |
On
Synergy devices the default "Core Clock" value for SWV usage should
be set to the same as the system clock (in Mhz).
For S7 devices (where the trace clock is halved) this should be set at half
the system clock. |
IDE-22184
|
[PG]
missing elements in RX630 vector table |
Device
Support RX |
For
the RX630 device some elements (RIIC3) are missing in the vector table (typ. vecttbl.c) and subsequent elements have been shifted by
that. |
IDE-22051
|
RX111
SRFX file missing Temperature calibration registers |
Device
Support RX |
The
RX111.sfrx file is missing temperature calibration registers. |
IDE-18693
|
[FFW]
Current consumption issues for RX100 and RX200 |
Device
Support RX |
1.
Only the "USER I/F" is supported for power supply interface. Cannot
be used with "E2 expansion I/F". |
IDE-23495
|
Correct
the startup file of RZ/A2M |
Device
Support RZ |
If
current pin setting is enabled by Smart Configurator, the initial value
remains unchanged and the current setting can not
be switched. |
IDE-20598
|
RZ/G
debugger Renesas Device Support |
Device
Support RZ |
When
opening Renesas Device Support tab of e2 studio Installation Details dialog,
it is described that J-Link ARM is supported for RZ/G. |
IDE-10061
|
e2Studio
Installer Fails with Spaces in User Name (Windows) |
Eclipse
Platform |
The
e2 studio installer can fail when installing to machines where the user name
has spaces included in the name. |
IDE-23065
|
[Eventpoints][SIM]
Program execution works incorrectly for Execution Address (PC) Eventpoint +
trigger type = AND |
Eventpoints
plugin |
When
debugging RX simulator, the combination of event points will be treated as
OR, even if AND is specified. |
IDE-16696
|
A
warning dialog appears when re-debug project (eventpoint). |
Eventpoints
plugin |
When
connecting to debugger, Warning dialog for Eventpoint setting sometimes
appears and the following message is shown. |
IDE-9338
|
Get
correct number of HW breakpoints and eventpoints |
Eventpoints
plugin |
The
event count on Eventpoint View shows the total event count including hardware
break points which are set on source view as line break points. |
IDE-6616
|
Data
Access Event Break compare value always converted to hex |
Eventpoints
plugin |
When
adding a new Data Access eventpoint, the Compare value (on the Data Access
Settings tab) is always converted to hex and subsequently displayed in hex
even if the value entered does not include an 0x prefix. |
IDE-6605
|
Eventpoints
disabled when e2 studio first opened. |
Eventpoints
plugin |
The
enable state of eventpoints for any debug configuration is not restored when the
debug configuration is launched for the first time after e2 studio is
started. |
IDE-2246
|
The
RX simulator does not allow trigger count on data access events. |
Eventpoints
plugin, GDB server RX |
The
trigger count for data access event for RX simulator will be ignored. |
IDE-21782
|
Build
fail for project which has added -> remove -> generated code of r_sci_rx module module |
FIT
Configurator |
When
using the FIT configurator when adding and removing modules it can cause
subsequent build errors after re-generation and build. |
IDE-23942
|
E1
Emulator fails to connect |
GDB
server |
On
Windows 10, version 1803 in some situations the emulator fails to connect
when the connection setting is "Auto". To
work around change auto to the specific serial of the emulator you wish to
connect. |
IDE-8302
|
Semihosting - printf causes subsequent file
operations to fail |
GDB
server |
When
using semi hosting, having a printf command before
file io operations causes them to fail. |
IDE-4607
|
[BREAKPOINT]
(RL78)Behavior in the case
of the error by Add Watchpoint. |
GDB
server |
When
sub menu "Add Watchpoint" is performed from a Memory view, it seems
to have been registered correctly in the Breakpoints view even if there is an
error condition. |
IDE-22657
|
Profile
shows wrong data for RH850 |
GDB
Server RH850 |
When
measuring Profile with RH850, wrong measurement result may be displayed. |
IDE-5780
|
rh850
BPC events do not count in the status area of the eventpoints view |
GDB
Server RH850 |
The
counter of the event points in Eventpoint view will not be counted correctly.
|
IDE-5547
|
Trace
record event for READ access with compared data acquires information which
does not match it. |
GDB
Server RH850 |
To use the data access events as trace start, trace stop
or trace record for RH850 with E1 emulator, please do not use the
"Compare Settings" condition for the event. |
IDE-19310
|
[Profile]
Displayed data is not reliable If Trace view is OFF |
GDB
Server RH850, GDB server RL78, GDB server RX |
If
the Trace view is off, the Trace capacity (will be also used for Profile) is
set to default (usually, this is the minimum capacity). This then means that
the Profile data is not reliable. |
IDE-18598
|
The
value on the memory view is not updated with RL78/G11 |
GDB
server RL78 |
In
the memory view, when displaying the IO area and the memory area near the
address adjacent to the IO area, FF data may be displayed depending on the
display area. |
IDE-15236
|
Resume
will fail if 'Permit Flash Programming' is set to No for RL78. |
GDB
server RL78 |
If
'Permit Flash Programming' is set to No in the debug configuration for RL78 Emulator,
resume the program will fail. When debugging, please set this option to Yes. |
IDE-12733
|
[RL78/G10
with EZ] program doesn't suspend at reset vector |
GDB
server RL78 |
There
is a known issue when debugging RL78/G10 with the EZ emulator. In some
condition the program doesn't suspend at reset vector. |
IDE-8503
|
RL78
SmartAnalog Memory can't be read during execution |
GDB
server RL78 |
The
devices with a SmartAnalog(e.g. RL78/I1E) will not be able to memory read during
execution. |
IDE-7412
|
Setting
RL78 register fails |
GDB
server RL78 |
When
using RL78 the HL register value cannot be modified in some circumstances. |
IDE-2716
|
BeforePC events on IECube temporarily
hardcoded limit of 4 |
GDB
server RL78 |
Before
PC events on IECube temporarily hard coded limit of
4. |
IDE-12094
|
Coverage
feature of E20 can't show the data over banks. |
GDB
server RX |
E20
emulator has the coverage 4 * 4MB blocks for RXv2 core devices. This block is
aligned with 4MB boundary. If the program executed from the block to the next
block without branch, the coverage from the top of next block to the first
branch will not be recorded. |
IDE-9045
|
Connection
Exception with RX64M GR-KAEDE Board using last known connection |
GDB
server RX |
Project
based variables in the debug configuration are not evaluated correctly at
launch and the launch then fails. |
IDE-8579
|
Execution
time for the last function may not be displayed in Profile View. |
GDB
server RX |
In
Profile view, execution time for each function is calculated for the function
which is returned out. If the execution stopped at the middle of the
function, execution time of the function may not be added. |
IDE-4982
|
[RX]
The debugger works same as 'Equals' even if I select 'Not Equals' in
'Comparison:' of 'Data Access Settings'. (only when 0x0 is specified to Mask
Value) |
GDB
server RX |
When
a data access event for RX is set with the data mask value as 0, the
comparison will be treated as "Equals" and the data mask value will
be treated as 0xFFFFFFFF. |
IDE-874
|
[BREAKPOINT
ISSUE]: Execution Address Eventpoints with trigger count do not work with
Breakpoints on Segger RX |
GDB
server RX |
Execution
Address Eventpoints with trigger count do not work with Breakpoints on Segger
RX. |
IDE-5770 |
Memory
View for RX Little Endian shows IO endian reversed |
GDB
server RX, IO view plugin |
RX
targets and IO registers greater than 1 byte. |
IDE-19750
|
[RZ/A1
Eventpoint] Eventbreak using Compare settings does
not work |
GDB
Server RZ |
when
using the RZ/A1 and debugging using Eventpoints. Event break using the
"Compare settings" feature does not work correctly. The program
will always stop regardless of the compare settings. |
IDE-7524
|
RZ/T1
Reload doesn't work on RAM_BOOT project |
GDB
Server RZ |
For
RAM based RZ-T1 projects a redownload of code will trigger a reset that
erases the RAM making further debugger operation impossible. The workaround
is to instead disconnect and then reconnect. |
IDE-12571
|
Not
possible to ALeRASE ID to erase device when ID byte
is programmed under e2studio |
GDB
Server Synergy |
Currently
the use of the special ALeRASE ID code unlock does not
work correctly with e2studio. The device will remain locked. The workaround
is to use the ALeRASE code in the RFP tool instead.
|
IDE-9057
|
[Trace
view] The Filter + Find feature seems not work correctly with Synergy project
|
GDB
Server Synergy |
Trace
find and filter functionality is currently not supported
for ARM-based devices |
IDE-8461
|
NO
TRACE ON S3A7 |
GDB
Server Synergy |
On
Synergy S3-based devices the trace can sometimes fail with 0 records. |
IDE-23388
|
Add
a limitation about software breakpoint in help. |
Help
|
Software
breakpoints can work only in internal ROM area and internal RAM area. Other
areas are not supported. |
IDE-18748
|
RL78
Plug-in Fails in Debug Mode Unless Code Generator is added to Project |
IAR
plugins |
When creating a IAR RL78 project (v3.10.1) for the E1
emulator and the RL78 G14 device the debugger connection does not work
correctly. |
IDE-7277
|
[IAR][RL78]
Linker extra options were not imported |
IAR
plugins |
In
some cases the IAR project importer does not
perfectly import all set build options. |
IDE-17642
|
Synergy
IAR static lib project cannot be converted to exe |
IAR
plugins, Renesas Synergy |
When
generating a Synergy static library project using the IAR toolchain it is not
possible to change the build artifact to Executable (IAR). |
IDE-7508
|
CCRX:
Warning dialog shows many times on Turkish OS when input 'i'
key for e2 studio location |
Installer
|
Problem:
|
IDE-18830
|
IO
Registers accessed with disregard for initial setup of register |
IO
view plugin |
There
is an issue that the reset values of a peripheral register that were
different than the user manual was stating. |
IDE-21522
|
Previous
toolchain version shown in build settings if changing configurations after
clicking "Apply" |
Managed
Build |
In
the build settings dialog if you select a new build configuration or try to
select the current configuration again after changing the toolchain version
you will see the previously selected toolchain version displayed. |
IDE-16830
|
The
"Project Upgrade Required" pop-up does not appear on subsequent
imports of the same project |
Managed
Build |
The
"Project Upgrade Required" pop-up does not appear on subsequent
imports of the same project when you delete and re-import in the same
session. |
IDE-16117
|
"Build
Automatically" does not rebuild after "Clean" CCRX project |
Managed
Build |
Even
if you specify "Build automatically", Build will not perform
automatically. |
IDE-5897
|
Build
error when project path has Chinese/Japanese text. |
Managed
Build |
When
operating e2 studio in a path that has Chinese or Japanese in the path names
you may experience problems invoking the application. Please rename the
directory with alphanumeric characters. |
IDE-1616
|
The
options of a Build Configuration were not correct after specifying “Multiple
Configurations...” functionality. |
Managed
Build |
The
options of a Build Configuration were not correct after specifying Multiple
Configurations... functionality. |
IDE-16491
|
Set
select an option in Tool Settings tab from Properties dialog |
Memory
Usage plugin |
Button
"Open Map file output page" dialog" and "Open Section
page" dialog will open "Properties" page. Please jump to
"Settings" tab by selecting "C/C++ Build->Settings". |
IDE-9494
|
Memory
view address caption should match to endianess |
Memory
View plugin |
Users
may misunderstand the data order in the memory view due to the address column
heading. |
IDE-8875
|
GDB
Server will crash when Start address is larger than End address in
Find/Replace/Fill Memory dialog |
Memory
View plugin |
e2
studio can crash when the memory view Find/Replace/Fill feature has a start
address larger than the end address. |
IDE-23064
|
[MisraC in editor] invalid path for linked file. |
MISRA-C
plugin |
MISRA-C
In Editor Checker plugin can check MISRA-C rules for
external source file normally. |
IDE-16103
|
[IT]
[Misra-C Checker plug-in] Violations list still
display when user changes language of source file |
MISRA-C
plugin |
Violations
list still display when user changes language of source file from C89 to C99.
|
IDE-23483
|
MMU
view - save function doesn't work |
MMU
View |
If
there is no entry for secondary page table in primary page table, page table
data cannot be exported to csv file. |
IDE-21688
|
MMU
registers and page table are not displayed on MMU view if MMU view is opened
after tartget is connected |
MMU
View |
If
MMU view is opened after the target is connected, MMU registers and page
table are not displayed. |
IDE-5637
|
(RH850)
Disassembly result of PE1 is different from the result of PE2. |
Multicore
Debugging RH850 |
For
RH850 multicore devices, disassembly result may be different from the
expected. In this case, please refresh the view after changing the debug
context to the other PE. |
IDE-9685
|
Performance
result is sometimes not displayed if "Pin to Debug Context" is
selected |
Performance
Analysis |
When
"Pin to Debug Context" is selected, Performance Analysis view,
Profile view, Trace view, Coverage view could be displayed incorrectly
sometimes. |
IDE-21897
|
Cannot
show Profile data when opening the view |
Profile
plugin |
Profile
data is only displayed in the profile view when the view is open during the
debugging operation. |
IDE-8303
|
An
internal error for “Acquiring Profile Result” may be shown when the program
stops/starts |
Profile
plugin |
An
internal error for "Acquiring Profile Result" may be shown when the
program stops/starts |
IDE-9032
|
"Rename
& Import Existing C/C++ Project into Workspace" option allows the
use of illegal characters in the new project name |
Project
Generation Core |
Rename
and Import Existing C/C++ project does not have the same restrictions as new
project wizard. |
IDE-8555
|
Unable
to create a synergy project in Turkish Windows 8.1 |
Project
Generation Core, Renesas Synergy |
When
using Turkish Windows with Synergy you may experience problems creating a
project. |
IDE-7333
|
1ms
refresh interval in expressions using RX Simulator does not work |
Real-time
Watch |
When
using the RX Simulator with real-time expressions if you use 1ms real-time
interval the expression view goes blank. On suspend, e2 studio appears to
hang while messages are processed. |
IDE-22881
|
The
TB_S3A6 & TB_S5D5 are breakdown with IAR building problem |
Renesas
Synergy |
When
using the CDT Toolchain Editor to change the toolchain from IAR version 7 to
IAR version 8 the project is modified in such a way that it no longer builds.
Please back up your files before starting such an operation. The
secure builder command line pattern and the linker script are modified to
invalid values during this process. Reverting
these commands to their previous settings should remedy the problem. |
IDE-11337
|
Copy
and paste support in the threads page of the Synergy editor needs e2Studio
RESTART to work correctly |
Renesas
Synergy |
In
certain situations, it is possible for the copy/paste actions to stop working
in the Synergy editor, threads page. If this happens please close the Synergy
editor and re-open it. Copy and paste should then work correctly. |
IDE-9612
|
[Eventpoint]
Red X icon is shown when setting Eventpoint for Synergy project |
Renesas
Synergy |
On
Synergy devices, repeated setting of Trace Start and Stop eventpoints can
lead to a situation where the eventpoints fail to set. |
IDE-8980
|
Headless
Build error with Synergy project |
Renesas
Synergy |
When
using the eclipsec.exe tool and running headless builds it is possible to see
an error created as seen below: |
IDE-10147
|
Switching
Board(not save) make project settings changing
unexpectedly |
Renesas
Synergy, Synergy Editor |
When
using the Synergy configurator if the device is changed on the BSP tab the
build options are now modified. |
IDE-8726
|
Exception
was thrown when specify synergy license file by place-holder |
Renesas
Synergy, Synergy Preferences |
When
using a placeholder in the Synergy license dialog it throws an exception.
Please use a full path to the file. |
IDE-23623
|
Drive
capacity settings are not displayed for P0_0 and P0_1 |
Smart
Configurator |
In
the Smart Configurator for RZ/A2M, the drive control setting is not displayed
for the port P0_0 and P0_1 in the Drive Control column of the Pin Number
list. Even though the setting is not displayed and the value to set the drive
control is not generated to the configuration table in r_gpio_drv_sc_cfg.h,
the drive control settings for these ports are fixed to 4mA. Please recognize
the driver control settings for these pins to be 4mA. |
IDE-23622
|
Drive
capacity 4mA cannot be selected for PG_2 to PG_7 and PJ_0 to PJ_5 |
Smart
Configurator |
In
the Smart Configurator for RZ/A2M, “4mA” cannot be selected for the port PG_2
to PG_7 and PJ_0 to PJ_5 in the Drive Control column of the Pin Number list
even the though output is selected for the direction of these ports. To set
the drive control of these port to 4mA, please modify r_gpio_drv_sc_cfg.h
to change the value of drive control settings for corresponding port in the
configuration table from “GPIO_CURRENT_8mA” to “GPIO_CURRENT_4mA” manually
after executing code generation. |
IDE-23621
|
Pin
interrupt can be enabled for analog input pins |
Smart
Configurator |
Pin
interrupt cannot be enabled if the pins were assigned to analog
input function (AN000 to AN007). |
IDE-23620
|
Pin
interrupt can be enabled for IRQ pins |
Smart
Configurator |
When
a pin assigned to IRQ function, the pin cannot be used for pin interrupt as
specified in hardware specification. |
IDE-23619
|
Input
can be selected for the port JP0_1 |
Smart
Configurator |
In
the Smart Configurator for RZ/A2M, “I” (input) can be selected for JP0_1 in
the Direction column of the Pin Number list even though this port have only an output function. Please do not select input
for this port. |
IDE-23618
|
Output
can be selected for the port P5_2 to P5_7, PL_0 to PL_4 |
Smart
Configurator |
In
the Smart Configurator for RZ/A2M, “O” (output) can be selected for the port
P5_2 to P5_7, PL_0 to PL_4 and JP0_0 in the Direction column of the Pin
Number list even though these ports have only input function. Please do not
select output for these ports. |
IDE-9873
|
"Show
in Smart Manual view" button does not work correctly |
Smart
Manual plugin |
"Show
in Smart Manual view" button does not work correctly when the active
project does not contain file which showing on editor. |
IDE-19495
|
Build
fails with secure builder required error after Migrating IAR 7.x tool chain
project to IAR 8.x |
Synergy
Builder |
The
following workaround can be used to migrate projects with IAR7.x to IAR8.x |
IDE-22323
|
Thread
property view does not update when select different thread |
Synergy
Editor |
When
using the Synergy configurator if you maximise the Threads page in the Workbench
the selection of thread is not captured correctly. This
means the properties view does not update correctly. Stop maximising the
Configurator if you experience this issue. |
IDE-22061
|
Synergy
editor fails to open 7.0 project with different SSP version |
Synergy
Editor |
Synergy
projects which are created in version 7.0 cannot be opened in earlier e2
studio releases. |
IDE-8165
|
The
stack size of GCC-RL is incorrect for a few devices |
Target
Information Tool |
For
the devices: |
IDE-23679
|
First
Value of the Run-break time measurement on Reset of the Debug Session is not
correct. (RL78 IE Cube) |
Time
Measurement |
The
value of the run-break time measurement displayed when resetting the debug
session is not appear correct. This is with RL78G13 IE Cube. Subsequent
executions show the correct value. |
IDE-23614
|
First
Value of the Run-break time measurement on Reset of the Debug Session is not
correct. (RZ and R-Car) |
Time
Measurement |
The
value of the run-break time measurement displayed when resetting the debug
session is not appear correct. This is with Segger J-Link for RZ. Subsequent
executions show the correct value. |
IDE-23248
|
Trace
view doesn't show the result of the first execution. |
Trace
plugin |
When
debugging RX, Trace view may not show the result for the first execution
after connection. In this case, please re-set the Trace acquisition setting
before execution. |
IDE-19773
|
Trace
recorded data is sometimes duplicated |
Trace
plugin |
After
the first time executing user program, sometimes the data is displayed twice
in Trace view. Please refer to the Cycle number column to decide a correct
Trace data. |
IDE-12609
|
Trace
view cannot be scrolled up |
Trace
plugin |
Trace view supports "find" trace record feature.
If found record is out of the list of trace records be showing in Trace view,
then Trace view will jump to shown records around found item but in this case
scrolling trace view up will not work. |
IDE-16926
|
Real-time
update does not work when debugging multiple projects while one is suspended |
Visual
Expressions plugin |
When
debugging more than one project simultaneously Realtime Update will not work
when any project is suspended. |
164 issues
Closed Tickets Requiring Inclusion in Release Note:
Key |
Summary |
Component/s |
Release
note |
IDE-21866
|
Link
information lost when files imported into new project |
Application |
When using the import and rename project import feature in
e2 studio any projects with linked resources do not import as expected. When
importing the linked resource links are broken. |
IDE-9507
|
Setting
breakpoint in function referenced in expression view causes debugger to hang |
Application
|
Setting
a breakpoint to a function which is referenced from an expression in the
expression view causes the debugger to hang when execution is resumed. When
this happens e2 studio must be restarted to resume normal operation. |
IDE-23405
|
GCC
for Renesas RZ C/C++ Library Project can't build when RZ/A2M device is chosen
|
ARM
GCC Plugins |
RZ/A2M
library project has predefined symbol definition as "-DAPPLICATION
PROJECT" compiler option and it prevents project build. |
IDE-21121
|
【RZ/A1】Symbol table isn't loaded |
ARM
GCC Plugins |
Following
conversion to the latest e2 studio 7.0 you may experience a problem debugging
RZ. This is due to the symbol table not being loaded. |
IDE-21881
|
RZ/G
build plugins do not show toolchain tab |
ARM
GCC Plugins, RZ/G |
When
using RZ Linux target projects for RZ/G and RZ/A the settings dialogs is
missing a toolchain tab. This makes it hard to see which toolchain is in use
and it is not possible to change the toolchain. |
IDE-21784
|
Divide
output file of binary file cannot be specified correctly. |
CCRL
Build plugin, CCRX Build plugin |
(CC-RX
and CC-RL) |
IDE-22970
|
[Builder][CCRX]
'.mot' file (converter phase) is not generated when importing/building
an old project (e2s v5.4) |
CCRX
Build plugin |
When
importing and building a CCRX project from 5.4 or before the '.mot' file is not generated. |
IDE-21564
|
some
builtin functions are not implemented in CCRXmachine.c |
CCRX
to GCC Converter |
When
converting CCRX to GNURX using the import and convert tool the wrapper function
file CCRXmachine.c is generated in the converted
project from CCRX to GNURX. |
IDE-21895
|
e2studio
takes a long time to respond when adding a new address range on Source
Coverage. |
Coverage
plugin |
e2
studio can take a long time to respond when adding a coverage range.
Especially if the range covers a large address range. |
IDE-20441
|
Exception
throws when SDMA1 project getting coverage result |
Coverage
plugin |
When
using the coverage in SDMA1 project, sometimes the exception occurs. Please
ignore the exception or disable coverage view in case coverage function is
not used. |
IDE-21934
|
[CS+
export/import] Export Renesas Common Project File, import again, build fail |
CubeSuite+
importer/exporter |
(Import/Export
CS+ project) |
IDE-21405
|
Import
the .rcpe file of multi
project, project chip information becomes incorrect. |
CubeSuite+
importer/exporter |
(Import
CS+ project) |
IDE-6493
|
Setting
an invalid value is allowed in E1 debugger for RX |
Debug
Configuration |
For
the debug configuration of RX, 'Operating Frequency [MHz]' is not validated
and therefore wrong values can be accepted with no warnings. Please confirm
if the appropriate value is configured as operating frequency. |
IDE-21896 |
Hotplug combo box for RL78 is disabled when debug configurations
dialog opens. |
Debug
Configuration RL78 |
When
the debug configuration for RL78 is opened, hot plug may be disabled even if
the selected device supports it. In this case, please close the configuration
and reopen it. |
IDE-16640
|
Add
ability to load symbol files at specified location and offset on reload |
Debug
Launch |
Currently
there is no way to load symbol files at specified location and offset when
debugging a Linux target for RZ/G. |
IDE-22456
|
RL78
incorrect stack address in linker script generated at project creation |
Device
Support RL78 |
RL78
linker scripts used for project generation have been corrected to fix various
errors. |
IDE-19932
|
GDB
try to write memory for breakpoint. |
GDB
RH850 |
Unexpected
memory modification will happen if software breakpoint is set when software
breakpoint resource is unavailable. |
IDE-20967
|
ACC0/ACC1
does not accept a large value. |
GDB
RX |
ACC0/ACC1
register for RX will not accept the value over 0x8000000000000000 in
Registers view. If it is specified, incorrect value will be set. |
IDE-19721
|
The
buttons on Trace toolbar and Resume button are disabled |
GDB
Server RH850, Trace plugin |
When
debugging RH850, if trace mode is changed to "Fill until full" and
resume the program, suspend will not work. Please don't use "Fill until
full" for trace mode. |
IDE-21809
|
Software
breakpoint should be able to use after hotplug for
RL78. |
GDB
server RL78 |
When
connection is established using hot plug functionality for RL78 it should be
possible to use software breakpoints. Currently software breakpoints are
restricted after connecting using hot plug. |
IDE-20448
|
Trace
view shows different data according to Disassembly view |
GDB
server RL78, Trace plugin |
When
using Trace view for RL78 simulator, the disassembly mode will not work
correctly (unexpected instruction will be displayed for the address which is
not the top of the instruction). Please see the information with BUS mode. |
IDE-22076
|
ACC0/ACC1
does not work with RX big endian. |
GDB
server RX |
RX
V2/V3 core device is used with” big endian”, the ACC0/ACC1 register cannot be
read or write correctly on the register view. |
IDE-22070
|
Trace
full break is cancelled if hardware breakpoint is set. |
GDB
server RX |
In
case of using RX with Emulator, if trace mode is set to "Fill until full
then break", it will be canceled when the
status of hardware breakpoints is changed. In this case, please re-set the
trace mode to "Fill until full then break" again. |
IDE-21063
|
Profile
result is not stable when connect with RX simulation |
GDB
server RX, Profile plugin |
When
connecting project with simulation, profile result is not consistent between
executions. The average execution time of the same function can change after each
very much after each time measuring data. |
IDE-21225
|
[RZ/T1]
Debugger is terminated when updating the value of the register
'CP15_c13_TPIDRURW' |
GDB
Server RZ |
RZ/T1
debugger is terminated when updating the value of the register
'CP15_c13_TPIDRURW' from the Registers view. |
IDE-20690
|
【RZ/A1】The address of the
breakpoint shifts next line. |
GDB
Server RZ |
In
some cases when setting a breakpoint, it will be shifted to the next line.
This can happen on the function entry points in some situations at the
debugger skips the function prologue. |
IDE-21872
|
[Help][RL78]
hot plugin prerequisites should be described |
Help
|
To
use hot-plugin for RL78 devices, there are multiple prerequisites as follows:
|
IDE-21788
|
MemoryUsage cannot show the struct member. |
Memory
Usage plugin |
struct
and union symbols are not displayed in the memory usage view, other types of
symbols are displayed as expected. |
IDE-21728
|
Memory
Usage displays incorrect when specifying -show=relocation_attribute
of Linker option. |
Memory
Usage plugin |
Memory
Usage issue: This issue occurs by CC-RX project. |
IDE-21224
|
[Profile][RX64M+E20]
This view and its button "Turn Profiling On/Off" are disable when
debugging with "External trace used for" = Trace |
Profile
plugin |
For
RX64M + E20 emulator, after debugged with “External trace used for" =
"Coverage", debug again with “External trace used for" =
"Trace" will make Profile view disabled while it should be enabled.
|
IDE-22042
|
Build
refers to the old library after changing the board and build the project |
Renesas
Synergy, Synergy Builder |
When
creating a Renesas Synergy project with the IAR toolchain and selecting the
crypto HAL AES module in SSP. Changing the device causes an incorrect library
to be linked. |
IDE-22389
|
RZ/G
Toolchain tab not populated when first opened |
RZ/G
|
When
importing existing RZ/G project from 6.x, the toolchain will be migrated to
latest version and will not retain toolchain selection from imported project.
|
IDE-21795
|
Unnecessary
parentheses are displayed in candidate list |
Smart
Manual plugin |
Unnecessary
parentheses are displayed in candidate list of Smart Manual view. |
IDE-20379
|
[Trace]
"Address" and "Now" column are empty in Source mode |
Trace
plugin |
In
Trace view, [Address] and [Now] column are always
empty in Source mode now. |
IDE-20378
|
Forward
and backward buttons on Trace toolbar are disabled when selecting any source
line |
Trace
plugin |
Step
forward, Step backward, Run forward and Run backward
buttons on Trace toolbar will be disabled when selecting any source line. |
IDE-20182
|
Disassemble
in Trace View doesn't finish [GUI] |
Trace
plugin |
When
using E20 for RX with 38pin trace cable, if disassemble mode is specified in
Trace View the disassemble may no finish. To avoid
this, please set the check for "Enable Timestamp Display" ON in
Trace acquisition setting. |
37 issues