List generated on 13/07/2020 16:14:31
Open Issues Requiring Inclusion in Release Note:
Key |
Summary |
Component |
Description |
IDE-36367 |
[RL78] Modify 1 byte data at specific address in DATA flash area causes the 1byte at neighbour address change to FF |
GDB server RL78 |
For RL78 devices debugging with E1/E2/E2 lite, if modify 1 byte memory at a specific address in DATA flash area, the 1byte at neighbour address changes to FF automatically. To avoid this problem, please modify memory in 2 bytes (or more) format. |
IDE-36222 |
RA Smart demo doesn't work with e2 studio 2020-07 |
Smart Demo |
When using the demonstration feature for RA project generation this feature does not work well in 2020-07. When attempting to use this feature an exception is thrown. |
IDE-36207 |
Debug fails with FreeRTOS and EK-RA6M4 ES hardware |
Debugging RA |
When using an RTOS on some RA6 hardware it is possible that the debugger will lose control after the RTOS has started up. To workaround, disable the RTOS integration from the Debug Configuration (Debug Tool Settings page). |
IDE-36041 |
RVDC does NOT show data when multicore devices such as RZ/T |
Debug Console plugin |
When creating Launch Group with 2 different RZ/T projects which have 2 different cores. The second project can show data on Renesas Virtual Debug Console but the first project cannot. |
IDE-35952 |
[RX] SETPSW instructions are not disassembled in debugger |
Debugger |
When debugging with RX devices, the SETPSW instructions are not disassembled by the debugger. |
IDE-35942 |
[CCRX][CCRL] objs are not deleted by project clean |
CCRL Build plugin |
If source files are located at project root, *.obj and *.d files in Configure folder (e.g.HardwareDebug/*.obj) will not be removed by clean project command. Workaround: User can delete them manually. |
IDE-35898 |
No pin assignment for new FreeRTOS (with IoT libraries) project |
RTOS Configurator |
When creating new FreeRTOS (with IoT libraries) project, software components are automatically added (e.g. r_ether_rx). However there is no pin assignment (e.g. pin assignment for r_ether_rx). If users do "Generate Code" on Smart Configurator, there is no generated code for pin, it can cause build error. In this case, it is suggested that users should do pin configuration before generating code. |
IDE-35778 |
Change Device preview caption is opposite for New/Current |
Managed Build |
When performing a device change the build setting preview shows the new values as "Current" and current values as "New" |
IDE-35746 |
Code Assist Page show incorrect information |
CCRX Build plugin |
As current behavior, when check on the check box "Use FIT Configrator" at page "Select Coding Assistants Setting" of None RTOS project, click back and select FreeRTOS then click next to go to "Select Coding Assistants Setting" page again. The check box "Use Smart Configurator" is unchecked. Work around solution: click Back and click Next again, the check box "Use Smart Configurator" will be checked. |
IDE-35635 |
On RL78 simulator, time measurement when the device is in standby mode does not work correctly |
Device Support RL78 |
On RL78 simulator, when the program is on standby (in halt, stop, or snooze mode for an RL78 device), the run-break time is not correctly measured in the following cases. • Suspended a program in standby mode. • A program is run following standby mode (run after suspended). |
IDE-35319 |
Command "-break-insert " is still displayed in GDB console of non-active thread |
Application |
In some situations the enabling the "Restrict new breakpoint to active debug selection" toolbar button is not restricting the breakpoint to the debug selection. With 2 simultaneous simulator sessions it adds the breankpoint to both debug contexts. |
IDE-35283 |
Enable Debug view to show call stacks for rtos threads (ARM + E2 Emulator) |
GDB Server E2 ARM |
"RTOS Integration in Debug view" is set to yes/no does not take effective for RA devices debugging with E2 emulator. It means only one main thread shown on Debug view even if project with FreeRTOS has many threads. |
IDE-35280 |
"Migration nedded" dialog appear when reopening Debug configuration dialog |
Device Support RX |
Sometimes, when changing Debug Hardware in Debug Configuration to Segger JLink, "Migration needed" dialog will be appeared unexpectedly. Please close this dialog and other action will work normally. |
IDE-33999 |
Exclude from upgrading the legacy projects with read-only files |
ARM GCC Plugins |
None |
IDE-33927 |
Should not count number of HW Breakpoints as evenpoints when they do not share HW resource |
Eventpoints plugin |
If debugging ARM device with E2 emulator, when setting hardware breakpoints they will be counted as eventpoints on Eventpoints view. Please ignore them from the number of eventpoints. |
IDE-33914 |
Program does not step correctly for SOTB when library generator enabled |
ARM GCC Plugins |
Selecting an ARM toolchain that has libgen installed when creating a new RZ project, will cause the program to go to the default handler when stepping, after returning from function on SOTB board. There are 2 workarounds for this: 1. Use a toolchain that doesn't have libgen installed 2. Choose the options : Project-built, Optimized for Library Generator when creating the project and changing the selected options to Pre-built, Newlib after the project was created, by going to Settings->Library Generator. |
IDE-33869 |
Cannot create RZ project when user folder has space |
Project Generation Core |
If a the Windows profile user name has a space within it, such as "John Smith" it can cause problems when creating projects. A RZ project cannot be created in case user folder has white space. An error dialog will be displayed. Please change the workspace to an area without a space. |
IDE-33682 |
Eventpoint is not unchecked automaticaly when setup fails. |
Eventpoints plugin |
When using J-link with RA, when setting a start tracepoint event it appears that the eventpoint is not set. A warning icon is displayed. However the event point still works as expected. |
IDE-33492 |
Loading e2studio7.7 project into e2studio 2020-04 and gereated code, some code is different comparing with previous |
Code Generator plugin |
For CG RL78/D1A,after loading project (e2studio project or AP3 project) which is saved on 32-bit environment in 64-bit environment, TAU0 channel1 input selection (refer to the red box in the figure below ) can’t be kept. |
IDE-33473 |
Watch point doesn't work on ARM V8M Devices(RA2A1,PEAKS,STAR) with J-Link |
Debugging RA |
When using the J-Link debugger for ARM V8M devices (Synergy S1JA,RA2A1,.etc) When setting Watch points, if the [Compare Setting] option is not being used then please set the [Data Access Setting]/[Size] to "Byte". Other settings will cause the break event to be missed or unexpected break events to happen. |
IDE-33403 |
RA E2 Emulator: Data-flash is not erased Even if "Erase on-chip data flash before download" = Yes |
E2 Emulator |
When using the E2 emulator with the RA device family the data flash is not erased even if "Erase on-chip data flash before download" = Yes. If the download module is not located in the data flash area the data flash is not erased. |
IDE-33362 |
Set default of "Prevent Releasing the Reset for CM3 core" to Yes |
Debug Configuration RZ |
When debugging with the RZ/T1, the debugger option "Prevent Releasing the Reset for CM3 core" should be set default to "Yes" but It's default is set to "No" in the current e2 studio. |
IDE-33354 |
[RZA2M] Build fail due to space characters in workspace |
Project Generator GCC RZ |
RZ/A2M projects creating in a path containing spaces will fail to build. Either avoid using workspace paths containing spaces or edit the Assembler & Compiler include paths to wrap each path in quotes e.g Change ${ProjDirPath}/generate/os_abstraction/inc -> "${ProjDirPath}/generate/os_abstraction/inc" |
IDE-33279 |
"generate" folder is created after Change Device in Amazon FreeRTOS project for RZA2M |
Device Migration |
When changing device for a GCC RZ project using Amazon FreeRTOS additional device startup files will be incorrectly added to the project. To avoid this deselect "Project Files" in the change preview. |
IDE-32543 |
QE Tools removed with Update from 7.6 to 7.7 |
Installer |
When updating e2 studio versions using an installer any installed QE tools are removed and then must be reinstalled. To preserve QE tools during an update use the "Check for Updates" function in the "Help" menu to perform an online update. |
IDE-32530 |
Heap configuration settings not getting updated for AC6 compiler |
RA Configurator |
For a Renesas RA FSP project in e2 studio 7.6, setting the heap size property in the Configuration Editor for an RA project does not pass this modified heap value to the linker script options (AC 6.12). One workaround for this issue is for the user to manually edit the linker file (e.g. .scat) and set the heap size value in there as well. |
IDE-32212 |
Change eventpoint setting when program is suspended may change the content of trace data |
GDB server |
In case of using trace feature with RX200 or RX100 series, if event setting is changed before the trace information is displayed, the incorrect contents might be displayed. Please don't change the event setting before displaying trace information. |
IDE-32012 |
Breakpoint does not relocate after download |
Debugger |
When there ia active debug and a relocated breakpoint, when the download action is executed the relocated breakpoint marker is not shown correctly; it is shown on the requested line, not the relocated line as expected. |
IDE-31944 |
--fix-segments should be added (or not removed) with RA and E2/E2lite |
Debug Configuration |
When creating a project which uses the J-link ARM debugger a command line option --fix-segments flag is added to the additional GDB parameters on startup. If you then switch to using the E2 emulator this parameter is removed. Please add this parameter back into the command line to ensure it continues to work well. |
IDE-31863 |
Debugger crashed at variable array declared in stack frame |
Debugger |
Under some circumstances, evaluating a variable length array might show wrong results or even cause GDB to crash. This is known to happen when we try to evaluate a variable length array and the instructions that write the information regarding that array have not yet been executed. This is a GCC bug and can be found at https://gcc.gnu.org/bugzilla/show_bug.cgi?id=93380. One way to workaround this problem would be to use a fixed size array. Another workaround can be close the Variables View and open it again/ evaluate the variable length array once the code that initialises the memory has been executed. |
IDE-31495 |
[Stack Analysis] Stack tree for RA projects only shows overridden symbol |
Stack Analysis View |
Stack Analysis view may display incorrectly in below case: - C Project with RA device which have overridden function. Stack tree only shows one symbol for overridden function instead showing all functions. |
IDE-31476 |
Debug execution status is incorrectly reported after Restart under certain conditions |
Debugger |
When the debug Restart button is clicked, if it is not possible for the system to insert a breakpoint on main, the program will fail to load correctly and the Debug view will incorrectly report the program as running. Workaround: make sure there is a free breakpoint available (the maximum number of breakpoints is not already inserted) before clicking Restart. |
IDE-31450 |
[Trace] Button 'Run Backward' does not work as expectation |
Trace plugin |
When users press the Trace button 'Run Backward', the 10 next record is selected instead of the newest trace record |
IDE-31402 |
E2 Emulator: On-chip Data flash was always erased even if "Erase on-chip data flash before download" = No |
E2 Emulator |
In case of using RA devices with E2 or E2 Lite emulator, the option "Erase on-chip data flash before download" will not work if the download data for data flash area is not included. |
IDE-30689 |
JLink remote IP connection needs IP address and port parameter in Debug Configurations |
Debug Configuration |
It is now possible to configure JLink to select a remote IP name or address. However currently the user interface does not support this feature. It can be supported by adding extra commands in the debug configuration. Under the Jlink section in the Debug Connection settings you can select USB or IP. If IP is selected then you will need to specify an IP address/name and optionally a port number. GDB Server expects the command line parameter (examples): -uSelect= IP=192.168.56.1:8080 -uSelect= IP=localhost:0 -uSelect= IP=jlink.segger.com |
IDE-30613 |
RH850 debug configuration needs to support blank flash memory fill option. |
Debug Configuration RH850 |
When viewing flash memory in the Memory View, it can be confusing as the values for this memory type can be random for unwritten blank flash memory regions. This can then result in many false postives for memory changes, resulting in more memory changes than expected. (red text) To fix this the debugger supports detection and filling of blank addresses areas with a user specified hex byte value. There is currently no user interface support for this feature. So you need to add the following command parameters to the additional commands section of the debug configuration. The GDB commandline option is: -uBlankFlaskFill= BB with the blank fill value being 0xBB. Specifying this value enables the feature, by default it is off. |
IDE-30386 |
Creating RZ/G project lets you continue with no toolchain selected |
RZ/G |
Depending on the selected RZ/G device it is possible to create a project without the required toolchain. The RZ/G1 family uses the 32-bit Linaro and the RZ/G2 should use the 64-bit Linaro distribution. It also permits you to select a wrong combination of toolchain and device. If you select a project that needs one of these and it is not installed the project generator will let you proceed. This will mean your project will not build. Please download the correct toolchain and register it to fix this problem. |
IDE-30305 |
_interrupt not resolving in GUI until property is changed |
RA Configurator |
For the RA family and the Flexible Software Platform (FSP), CTSU is different than other FSP modules in that the interrupt priorities are currently macros instead of run time options. This causes a problem where once added the DTC activation sources are not resolving in the GUI. To work around this please go to the Properties tab and change any property for r_ctsu, then the strings will resolve correctly. |
IDE-30258 |
ARM DS AC6 toolchain definition doesn't specify binary parser |
ARM LLVM Plugins |
The ARM compiler 6 CDT managed build toolchain definition in DS plugins version 5.23.1 do not specify a "targetPlatform" and therefore does not specify a "binaryParser". This causes AC6 projects to not have a binary parser specified by default which means the .axf build artifact is not detected as a binary by CDT. |
IDE-30226 |
Cannot find binaries when debugging a project compiled with AC6 |
Debugging RA |
When using the Flexible Software Pack (FSP) and the RA family with the AC6 compiler when trying to debug you may see the error: No binaries found To overcome this issue please update the debug configuration as follows: Debug Configuration ->Renesas GDB Hardware Debugging -> Main -> C/C++ Applications -> Paste path to binary file (*.axf). |
IDE-30209 |
Eventpoints of RH850 are not restored correctly |
Debugging RH850 |
RH850 event points are not restored correctly on subsequent debug sessions. You will need to re-set the event points on subsequent debug launches. |
IDE-30101 |
GUI will be not responding when scrolling after filter on Trace |
Trace plugin |
When doing filter with big Trace Capacity (Trace Capacity > 1M), the filter job does not work, and you may see a TimeOutException. After that, if you do scroll Trace View, e2 studio will crash. Workaround: If the see TimeOutExecption when doing filter, wait about some minutes (~10 minutes) for the filter job finishes, then change the displayed mode (enable or disable one of BUS/DIS/SRC modes), filter result will be displayed and you can scroll Trace view as usual. |
IDE-30018 |
Console Find fails to report items which are indeed present |
Eclipse Platform |
Sometimes attempting to find some text in the Console view, using the Find/Replace dialog, fails. The workaround is to select in the Console you wish to find in, then attempt the find. |
IDE-29841 |
User dictionary setup is not clear |
Application |
When setting up a User Dictionary it is necessary to select "C/C++ spelling engine" in the Spelling preferences page before selecting the dictionary file |
IDE-29797 |
[Synergy-Linker Script] Error message is NOT shown when create duplicate Memory section on Graphical editor |
Linker Script Editor |
If a duplicated memory section name is created in the graphical linker editor it does not warn the user. |
IDE-28705 |
e2 studio crash relating to threads shown in debugger view |
GDB Server Synergy |
In some circumstances, when operating with many ThreadX threads that are also using large structures it can cause problems when refreshing the debug view after the debugger is suspended. In some cases the e2 studio application may appear to freeze and become unresponsive. if this is happening then the best method is to go to the Debug Configuration->Debug Tool Settings and switch off the RTOS Integration in the Debug View. |
IDE-28660 |
Trace does not show label for RZ/T1-QSPI project |
Debugging RZ |
In some cases when using the RZ/T1 device with the QSPI project, trace results do not appear to be correct. In some cases labels are not shown correctly and instead we get multiple instances of the address 0xFFFFFF0. |
IDE-28503 |
GDB Simulator Debugging (RH850) fails |
GDB RH850 |
The simulator provided in the RH850 GDB will not 100% operate as a functional simulator for RH850. The implementation is not complete. |
IDE-28354 |
"script" folder is not a source folder |
Renesas Synergy |
When using the Synergy device family with SSP the "script" folder, which contains the linker script files is not configured as a source folder. This means that this file when modified does not cause a rebuild of the project. Please clean your project and then rebuild it to avoid problems. |
IDE-28235 |
"Target not in non-stop mode" error dialog is shown |
Real-time Watch |
"Target not in non-stop mode" error dialog is shown sometimes when starting debugging. This can also happen when the user executes debug operations rapidly. Even though non-stop mode is not enabled in GDB settings, GDB turns it on automatically while starting debug. |
IDE-27960 |
[CG]_Cannot add Code Generator to supported IAR project. |
Code Generator plugin |
It is not currently possible to add the code generator to a RX IAR project which is using the version 4.x. An error will be displayed with the error message "The selected project is not supported by Code Generator!" Note: This issue does not occur with IAR Toolchain for RX (3.x). |
IDE-27850 |
CoreSight ITM: trace table disappear suddenly |
Trace - CoreSight Plugin |
When the content of the trace data is changed, the user is asked to refresh the updated data. After the update, the trace data editor is closed. The user needs to open the editor again to see the updated trace data. |
IDE-26789 |
[CG] the value of "Clock Generator"/"Peripheral function used" is shown inconsistently on 2 views (Code Preview and Peripheral Functions) |
Code Generator plugin |
Even though a periperal is used, it's peripheral infomation is empty on Code Preview property. e.g.) Step1/ Create a project using Code generator Step2/ Open the project on Project Explorer Step3/ [Code Generator]/[Code Preview]/[Clock Generator] -> right click and choose [Property] Expected: The value of 'Peripheral function used' is 'Used'. Actual: The value of 'Peripheral function used' is empty. |
IDE-26561 |
BRAVO project cannot execute Pre-build steps/Post-build steps with executing Build. |
IAR plugins |
Workaround is to switch off parallel build (project properties > C/C++ Build > Behavior tab > Enable parallel build set to unticked). After this workaround is performed, Pre-build steps and Post-build steps are executed during a build. |
IDE-26444 |
renesas_cc_converter crashes at build of sample program |
Loadmodule Converter |
renesas_cc_converter.exe might crash at build when using toolchains CC-RL or CC-RX. This might happen since e2 studio 7.0. |
IDE-26355 |
Build fail with S1JA project |
Renesas Synergy |
Please note that the S1JA device is only supported by GCC in SSP 1.6 or later. Earlier than that it was supported by the IAR toolchain only. |
IDE-25949 |
Project type -> IAR RX Executable missing |
IAR plugins |
Users are struggling to locate the IAR project generation menu items. The procedure for finding this is as follows: Just to check are you following these steps: File->New->C/C++ Project Click "C Managed Build" Click Next Find the IAR (Executable) entry |
IDE-25569 |
Build fails when import a project with blank character in the the project name |
IAR plugins |
When using the IAR plugins with a Synergy device if the project name has a space within it will cause the build to fail. The build will fail with and error regarding missing header files. |
IDE-25513 |
Disassemble view is not updated when re-downloading during debugger connection. |
CDT |
When redownloading a download module after rebuilding it the disassembly and other views may display old data until manually refreshed. |
IDE-25438 |
Debugger is disconnected when entering software standby mode. |
GDB Server RZ |
When using the RZ and debugging with J-link if the device enters software standby mode the J-link is disconnected. |
IDE-25376 |
e2 studio ThreadX control symbol addresses update when loading multiple elf files. |
GDB |
When using Synergy with ThreadX debugging problems can be caused when using multiple load modules. Subsequent changes to the ThreadX table are not recognised by the debugger and this can cause incorrect thread data to be displayed. To avoid this ensure the ThreadX table data is within the first load module downloaded by e2 studio. If this does not remedy the issue you can disable the Debug view ThreadX debugging within the debug configuration. |
IDE-25278 |
IAR synergy ELF files don't have a .text section |
Renesas Synergy |
When loading Symbols from multiple .elf files compiled using the IAR toolchain, the user will need to add ".text" before place in FLASH_region command inside the .icf Script. e.g. {code} ".text": place in FLASH_region { block LOCK_LOOKUP, ro, ro section .rodata, block QSPI_NON_RETENTIVE_INIT_BLOCK, block RAM_INIT_CODE, block USB_DEV_DESC_BLK }; {code} |
IDE-25273 |
Files not updated when changing the device |
ARM GCC Plugins |
When changing the device from a RZ/A1 and attempting to swap to a RZ/T1 the device migration is not successful. The source code is not migrated successfully and the build fails. This is due to the different start-up code structure between these devices. In this case please create a new project and copy the required source to the newly created project. |
IDE-25145 |
NullPointerException generated after excluding resource from build |
RX GCC build plugin |
When using the RX GCC builder and excluding either a .s or .SRC file from your project it can cause a null pointer exception on a subsequent rebuild. |
IDE-25087 |
Opening Measure Current Consumption View and then terminating debug session causes e2 studio to crash. |
Current Consumption View |
Opening Measuring Current Consumption (QE) view might cause e2 studio to not function properly any more and a restart might be required. |
IDE-24867 |
Mouse over of variable crashes GDB server or makes e2 studio hang |
CDT |
With certain projects that use RTOS Integration in Debug View and expose Threads that contain only the 0xfffffffe frame in the Debug Tree View, mouse hovering over strings or macros defined as strings can cause the debug session to become unresponsive or GDB to crash. |
IDE-24657 |
ITM Live Trace does not work after Trace (The Trace View) is enabled (even if it is disabled) |
Debugging Synergy |
The ITM Live Trace view does not work after the Trace is enabled in the standard Trace Window. Even if it is subsequently disabled. Terminating and re-starting the debug session with trace disabled in the trace window will then re-enable ITM Live Trace output. |
IDE-24190 |
Import legacy project with Japanese build mode name configuration |
Project Generation Core |
When importing user-created configurations with Japanese (multi-byte coded) names after importing into e2 studio the configuration names are reverted to English. When this problem occurs the options set in the configuration are lost. Therefore it is recommended not to use multi-byte characters for build configurations. The workaround would be to rename the configuration following import and then manually reset the options as they were before import. |
IDE-23373 |
Run commands behaviour after a reset from the UI is not consistent |
Application |
The GDB run commands which are setup on the debug configuration are not consistently applied. After the connection process they work correctly however on subsequent debugger reset operations the result is inconsistent. |
IDE-23325 |
CCRX Build shows an error, Failed to access a temporary file during build of large projects |
CCRX Build plugin |
[CC-RX project] When building with the CC-RX toolchain at random the following message can be displayed 'Failed to access a temporary file' error is thrown by build process. This occurs more frequently on larger projects with complex include paths, or paths with linked resources. If this happens please repeat the build and it will work correctly. |
IDE-23242 |
Rename and Import of 6.2 project into 7.x, then upgrade SSP, selects different pin configuration |
Renesas Synergy |
In the Synergy Configuration editor, when upgrading SSP version, or changing Board, where the selected device is not the default device for the selected Board, an incorrect Pin Configuration may be selected on the Pins tab. If upgrading SSP version or changing Board when in the Configuration editor, please check that the required Pin Configuration is still selected on the Pins tab. If not, re-select the required Pin Configuration from the drop-list. |
IDE-23028 |
Minimum and Maximum value are always 0 |
Coverage plugin |
When using Data Coverage to collect variables information, Maximum and Minimum column are always zero, this issue occurs on all supported devices |
IDE-22881 |
The TB_S3A6 & TB_S5D5 are breakdown with IAR building problem |
Renesas Synergy |
When converting from a project building with the IAR v7.x builder to using the IAR v8.x builder problems can occur. It has been noted that in some situations the linker file points to an incorrect linker file. e.g. After importing the project the Linker configuration file is set to "${workspace_loc:/${ProjName}/script/S5D5. When switching the tool chain to 8.x the linker configuration file is set to ${sdkLocation}/config/generic.icf Changing the linker file path back to the originally selected one should resolve this build error. |
IDE-22657 |
Profile shows wrong data for RH850 |
GDB Server RH850 |
When measuring Profile with RH850, wrong measurement result may be displayed. Profile measures based on Trace data, but there is no problem with Trace data. |
IDE-22266 |
Cannot start e2studio image due to Code Generator .Net Framework Exception |
Code Generator plugin |
This issue can occur when using multiple versions of e2 studio of the same version. If e2 studio is installed in one location and then another installation of the same version is installed on the same machine, then the older installation is deleted or moved. The code generator component which is registered in the registry no longer exists. This will cause problems with the other e2 studio installation as it will try and use the code generator component as defined in the registry. To avoid this run the tools within the Code Generator plugin directory of the e2 studio you are trying to launch. e.g. C:\Renesas\e2_studio\eclipse\plugins\com.renesas.cg_2.11.0.v20180601-1047\CodeGenerator\Tools\ First run "Unregister COM.bat" and then run "register COM.bat". This should solve the problem and allow e2 studio to work correctly. |
IDE-21737 |
RZ/A serial launch with Linux target doesn't show console output from target |
Debugging RZ Linux |
With ethernet based connections for Linux target debugging, e2 studio starts GDB server and captures output of the process. With Linux target, serial connection GDB server is started but the console output is not captured. |
IDE-21699 |
CodeGenerator cannot import AP3 project |
Code Generator plugin |
'AP3 for RL78' project file/ Code generator setting of other e2 studio project cannot be imported into e2 studio project even if the target device and toolchain are same. |
IDE-21649 |
[Breakpoint] Invalid breakpoint warning is lost after using Move To Line |
CDT |
After a move to line operation in the debugger the source window is updated and breakpoint warning markers are removed from view. |
IDE-21616 |
Connection will fail if max+1 breakpoints are set. |
Debugger |
If setting breakpoint is failed, the breakpoint is marked as exclamation in the editor view (or marked as un-checked in breakpoint view). In this case, if debugger is disconnected and re-connected, connection will fail. To avoid this, please remove the failed breakpoints before connection. And also, this will happen if "Set breakpoint at" is checked in the debug configuration, when the flash programming is disabled. In this case, please set the check OFF before connection. |
IDE-21601 |
RZ/A serial COM port doesn't work if port number is greater than 9 |
Debugging RZ Linux |
RZ/A serial COM port does not work if the port number is greater than 9. If Windows assign device USB COM port to 10 or above, then gdb can't find the port. gdb shows, "No such file or directory" |
IDE-21570 |
Code Generator does not work with project located in SVN/Git repository |
Code Generator plugin |
Code Generator is missing when loading the project shared to SVN/Git repository. |
IDE-21522 |
Previous toolchain version shown in build settings if changing configurations after clicking "Apply" |
Managed Build |
In the build settings dialog if you select a new build configuration, or try to select the current configuration again after changing the toolchain version you will see the previously selected toolchain version displayed. To avoid this either click "Apply and Close" after selecting the new toolchain or click "Apply" then close the dialog. |
IDE-20888 |
Add support for -mno-allow-string-insns in code generator |
Code Generator plugin |
Code Generator for RX doesn't support '-mno-allow-string-insns' of GCC compiler option. Selecting '-mno-allow-string-insns' causes a buid error about 'smovf' instruction in 'r_cg_reset_program.asm'. |
IDE-20843 |
Subversion Local Checkout - Database permanently locked |
Application |
When using the Subversion Eclipse plugin (Subversive) along with an external Subversion client some problems can be caused. Please use either the internal or external client. |
IDE-20598 |
RZ/G debugger Renesas Device Support |
Device Support RZ |
When opening Renesas Device Support tab of e2 studio Installation Details dialog, it is described that J-Link ARM is supported for RZ/G. However, JTAG debug for RZ/G is not supported. Only TCF connection debug for Linux application is supported. |
IDE-20542 |
e2s hangs when debugging a project and this project was closed |
Application |
e2 studio can hang when debugging a project and the project being debugged is closed. Please terminate the debugger before closing the Workbench. |
IDE-20425 |
[RZ] Project converter to fill FPU architecture option build fail |
ARM GCC Plugins |
Due to previous build plugin issues on conversion we add “.lib” to the build artifact output prefix in some conditions. Unfortunately, this can cause issues with some project types. If you experience an issue related to this please remove the “.lib” and rebuild. |
IDE-19750 |
[RZ/A1 Eventpoint] Eventbreak using Compare settings does not work |
GDB Server RZ |
when using the RZ/A1 and debugging using Eventpoints. Event break using the "Compare settings" feature does not work correctly. The program will always stop regardless of the compare settings. |
IDE-19495 |
Build fails with secure builder required error after Migrating IAR 7.x tool chain project to IAR 8.x |
Synergy Builder |
The following workaround can be used to migrate projects with IAR7.x to IAR8.x 1. Add environment variable SECURE_BUILD_COMMAND: ${renesas.support.targetLoc:synergy-build} /isdebuild 2. Update Command Line pattern IAR C/C++ Compiler for ARM setting if following command missing ${SECURE_BUILD_COMMAND} 3. Update Command Line pattern IAR C/C++ Assembler for ARM if following command missing ${SECURE_BUILD_COMMAND} |
IDE-18830 |
IO Registers accessed with disregard for initial setup of register |
IO view plugin |
There is an issue that the reset values of a peripheral register that were different than the user manual was stating. The root cause is that the IO register view in the debugger does not validate the MSTP register settings before presenting the data for the peripheral that is being viewed. |
IDE-18748 |
RL78 Plug-in Fails in Debug Mode Unless Code Generator is added to Project |
IAR plugins |
When creating a IAR RL78 project (v3.10.1) for the E1 emulator and the RL78 G14 device the debugger connection does not work correctly. As a workaround adding the code generator to the project and setting the debugger to "Used" will configure the start-up code and project to be debugged successfully. The IAR ILINK command file provides #define __RESERVE_OCD_ROM to allocate ROM area for debugging, however adding this into the settings still does not allow a successful connection. |
IDE-18693 |
[FFW] Current consumption issues for RX100 and RX200 |
Device Support RX |
1. Only the "USER I/F" is supported for power supply interface. Cannot be used with "E2 expansion I/F". 2. When monitor point is set,current consumption may be measured for a certain period even after user program stops. |
IDE-18639 |
Incremental build can break after renaming or copying a project |
CDT |
After renaming or copying a project incremental build might be broken & the project will perform a full build every time. If this occurs then: 1. Open project proprieties & go to the "C/C++ Build" -> "Refresh Policy" 2. Delete the old name of project folder, then add the new project name. |
IDE-18623 |
[RL78] Strange behavior with hardware breakpoint |
Debugging RL |
In case of using RL78, hardware breakpoint is realized by execution address after PC. This will cause several issues: - Temporary hardware breakpoint will not be removed after the breakpoint is hit. Therefore, the breakpoint will always hit. Please remove the temporary breakpiont manually after the breakpoint hits. - In case of RL78/G10 (or RL78 devices which flash programming is disabled), software breakpoint is not supported. Therefore, temporary hardware breakpoint will be used for the cases: * Stepping over * Stepping return * Run to line * "Set breakpoint at" is specified in the debug configuration * etc When using these operation, if breakpoints are used in the debugging program, the operation will fail. Please release 1 or more breakpoint before the operation. And please invoke GDB command 'delete breakpoints' in Debugger Console view to remove the breakpoint after the program is suspended by "Set breakpoint at main". If the breakpoint is kept as it is, it will always hit and the next operation such as stepping return or stepping over may fail because no breakpoints can be used for the operation. |
IDE-18606 |
E2 Studio "Console" view - "Renesas Debug Virtual Console" issues |
Debug Console plugin |
Renesas Debug Virtual Console's pin status will not be restored for next opening e2 studio. Please active and pin it manually before debugging to avoid loosing data. |
IDE-18598 |
The value on the memory view is not updated with RL78/G11 |
GDB server RL78 |
In the memory view, when displaying the IO area and the memory area near the address adjacent to the IO area, FF data may be displayed depending on the display area. Applicable devices are all devices of RL78 and RH850. The workaround is to display in Expressions view. |
IDE-18242 |
'Launch in debug mode' button on the top left of the window will kill the current process forcedly. |
Application |
When pressing the launch button on the launch bar when a debugger session is already in operation there is no warning message displayed. The current debugger session is terminated. If you wish to have more than one debugger session please use the Debug menu rather than the launch bar. |
IDE-17642 |
Synergy IAR static lib project cannot be converted to exe |
IAR plugins |
When generating a Synergy static library project using the IAR toolchain it is not possible to change the build artifact to Executable (IAR). e2 studio gives the impression that the operation was successful however when building no object files are generated. |
IDE-17089 |
Monitor point can't be set if NOP is not inserted at the top of the line. |
Current Consumption View |
When using monitor point insertion with CCRL 1.05 or CCRX 2.08 for the Current Consumption View, if nop is not inserted at the top address of the line because of the code generation or optimization, setting monitor point will fail. In this case, please insert NOP() in the source code manually. |
IDE-16926 |
Real-time update does not work when debugging multiple projects while one is suspended |
Visual Expressions plugin |
When debugging more than one project simultaneously Realtime Update will not work when any project is suspended. |
IDE-16874 |
Cannot connect to RZ if "Image Only" is selected as Load Image |
Debug Configuration ADAS |
When writing the PC register, GDB needs to know in what mode it is ARM or Thumb. Usually this is obtained from the symbol information but since the symbols are not loaded ("image only") GDB tries to obtain this from the cpsr value from current frame. However in this case there is no frame information which causes an error. There is a workaround, we can tell GDB what mode we are running so it doesn't try to read the cpsr register: set arm fallback-mode (arm|thumb|auto) GDB uses the symbol table, when available, to determine whether instructions are ARM or Thumb. This command controls GDB’s default behavior when the symbol table is not available. The default is ‘auto’, which causes GDB to use the current execution mode (from the T bit in the CPSR register). This can be added to the GDB [Startup]/[Initialization Commands] section in the debug configuration |
IDE-16830 |
The "Project Upgrade Required" pop-up does not appear on subsequent imports of the same project |
Managed Build |
The "Project Upgrade Required" pop-up does not appear on subsequent imports of the same project when you delete and re-import in the same session. To workaround you can right click on the project and select "Upgrade Legacy Project" or alternatively shut down e2 studio and re-open it. |
IDE-16801 |
[CC-RX] Some setting options is not updated correctly with user configuration and multiple configurations |
CCRX Build plugin |
[CC-RX project] If you specify options for multiple configurations using Multiple configuration, options may be specified for all configurations. (Ex: Endian option) In this case, specify options by each configuration. |
IDE-16744 |
Certificate approval screen can cause e2 studio to appear to lock |
Application |
The certificate approval screen which appears during automatic smart manual installation can cause e2 studio to appear to lock. If this happens you can select another application then going back to e2 studio to dismiss the dialog. |
IDE-16696 |
A warning dialog appears when re-debug project (eventpoint). |
Eventpoints plugin |
When connecting to debugger, Warning dialog for Eventpoint setting sometimes appears and the following message is shown. "Some eventpoints were disabled before being applied. This may have been caused by multiple eventpoints with trigger counts or address ranges". In this case, please disconnect debugger and connect debugger again. Or, please enable each event points manually. |
IDE-16491 |
Set select an option in Tool Settings tab from Properties dialog |
Memory Usage plugin |
[Memory Usage] Button "Open Map file output page" dialog" and "Open Section page" dialog will open "Properties" page. Please jump to "Settings" tab by selecting "C/C++ Build->Settings". |
IDE-16117 |
"Build Automatically" does not rebuild after "Clean" CCRX project |
Managed Build |
Even if you specify "Build automatically", Build will not perform automatically. Please perform the Build manually. |
IDE-16062 |
Code Generator not registered when installed in a seperate folder |
Code Generator plugin |
When e2 studio is installed in multiple locations on the user’s machine and they are same version, the Code Generator does not work. [Workaround] Please execute "CGRegister.exe" under /plugins/com.renesas.cg_x.x.x.vxxxxxxx-xxxx/CodeGenerator/Tools |
IDE-15894 |
Cannot delete Hew project on e2s 6.0 |
Application |
HEW projects cannot be removed from the workspace after importing a HEW project. Since HEW project has some read-only/hidden files. If you want to delete the HEW project, please delete the following read-only/hidden files first. - xxx.rxc, xxx.rxa, xxx.rxg, xxx.hlk |
IDE-15101 |
Cannot connect to EZ emulator when another debugger is connected. |
Debugging RL |
When using EZ emulator with RL78, if another emulator like E1 is connected to PC, connection to EZ emulator will fail. Please don't connect another when using EZ emulator. |
IDE-14439 |
Function called from group interrupt hadler should have prototype |
Code Generator plugin |
Generated function called from group interrupt handler does not have prototype. W0520223 occurs when C99 is selected or -change_message=warning option is specified. In the following case, r_sci2_transmitend_interrupt and r_doc_dopcf_interrupt shoud be declared by prototype --------- void r_icu_group_bl0_interrupt(void) { if (ICU.GRPBL0.BIT.IS4 == 1U) { r_sci2_transmitend_interrupt(); } if (ICU.GRPBL0.BIT.IS29 == 1U) { r_doc_dopcf_interrupt(); } |
IDE-12878 |
Enabling BSD sockets in ThreadX source code breaks RTOS Resources View |
Debugging Synergy |
When using the Synergy editor if you enable the BSD sockets in the ThreadX source code updates to the RTOS resources view and e2 studio debug view will no longer work correctly. |
IDE-12733 |
[RL78/G10 with EZ] program doesn't suspend at reset vector |
GDB server RL78 |
There is a known issue when debugging RL78/G10 with the EZ emulator. In some condition the program doesn't suspend at reset vector. |
IDE-12571 |
Not possible to ALeRASE ID to erase device when ID byte is programmed under e2studio |
GDB Server Synergy |
Currently the use of the special ALeRASE ID code unlock does not work correctly with e2studio. The device will remain locked. The workaround is to use the ALeRASE code in the RFP tool instead. |
IDE-12123 |
Follow on issues for Linker Script Editor |
Linker Script Editor |
The Linker Script Editor may report errors when using some Wild Identifiers such as 1file.o and *filename.o. Although these are valid file names and valid identifiers according to the Linker Script syntax, they need to be quoted when using the Linker Script Editor(e.g. "1file.o" and "*filename.o"). |
IDE-12094 |
Coverage feature of E20 can't show the data over banks. |
GDB server RX |
E20 emulator has the coverage 4 * 4MB blocks for RXv2 core devices. This block is aligned with 4MB boundary. If the program executed from the block to the next block without branch, the coverage from the top of next block to the first branch will not be recorded. |
IDE-11337 |
Copy and paste support in the threads page of the Synergy editor needs e2Studio RESTART to work correctly |
Renesas Synergy |
In certain situations it is possible for the copy/paste actions to stop working in the Synergy editor, threads page. If this happens please close the Synergy editor and re-open it. Copy and paste should then work correctly. |
IDE-10423 |
Automatic data flash erase on RL78 device during the debug session start via E1 |
Debug Configuration |
Erase flash on start-up option on RL78 should be executed once. When e2studio connects successfully to RL78 target and erases the flash, this option should return to false, so that flashing is not done every time target is connected. |
IDE-10147 |
Switching Board(not save) make project settings changing unexpectedly |
Renesas Synergy |
When using the Synergy configurator if the device is changed on the BSP tab the build options are now modified. However if the configuration is not saved the project options will still reflect the change made on the BSP tab if the core type was changed. E.g. from a Cortex M4 (S3A7, S7G2) to a S124 or S128. |
IDE-10108 |
Error Dialog is shown when disconnected. |
Debugging RX |
When hitting Disconnect on a running debug session (with breakpoints in use) the debugger will error and fail to disconnect Workaround: Only click Disconnect when the session is paused (the Disconnect operation will return the device to the running state automatically) |
IDE-10061 |
e2Studio Installer Fails with Spaces in User Name (Windows) |
Eclipse Platform |
The e2 studio installer can fail when installing to machines where the user name has spaces included in the name. If you can login with another user name such as “Administrator” then this problem can be avoided. |
IDE-9873 |
"Show in Smart Manual view" button does not work correctly |
Smart Manual plugin |
"Show in Smart Manual view" button does not work correctly when the active project does not contain file which showing on editor. |
IDE-9685 |
Performance result is sometimes not displayed if "Pin to Debug Context" is selected |
Performance Analysis |
When "Pin to Debug Context" is selected, Performance Analysis view, Profile view, Trace view, Coverage view could be displayed incorrectly sometimes. |
IDE-9612 |
[Eventpoint] Red X icon is shown when setting Eventpoint for Synergy project |
Renesas Synergy |
On Synergy devices, repeated setting of Trace Start and Stop eventpoints can lead to a situation where the eventpoints fail to set. Workaround: Disconnect and reconnect. |
IDE-9533 |
Fail safe break message not clear on RL78 IECUBE |
Debugging RL |
When the failsafe break is configured to "Stop on read from uninitialized RAM" on the RL78 IECUBE the break occurs but the cause is not clear. |
IDE-9494 |
Memory view address caption should match to endianess |
Memory View plugin |
Users may misunderstand the data order in the memory view due to the address column heading. The "Address" caption of Memory view is always the like "0 - 3", "4 - 7" regardless of the endian which is selected.. |
IDE-9393 |
Coresight SWV Clock setup needs improvement |
Debugging Synergy |
On Synergy devices the default "Core Clock" value for SWV usage should be set to the same as the system clock (in Mhz). For S7 devices (where the trace clock is halved) this should be set at half the system clock. |
IDE-9338 |
Get correct number of HW breakpoints and eventpoints |
Eventpoints plugin |
The event count on Eventpoint View shows the total event count including hardware break points which are set on source view as line break points. Events which can be set in Eventpoint view may be less than displayed. |
IDE-9101 |
Cannot launch debug session when breakpoint cannot be set |
Debugger |
If GDB is unable to set a breakpoint during the launch then the whole launch will be aborted. Removing the breakpoint(s) will allow the launch to complete successfully. |
IDE-9057 |
[Trace view] The Filter + Find feature seems not work correctly with Synergy project |
GDB Server Synergy |
Trace find and filter functionality is currently not supported for ARM-based devices |
IDE-9045 |
Connection Exception with RX64M GR-KAEDE Board using last known connection |
GDB server RX |
Project based variables in the debug configuration are not evaluated correctly at launch and the launch then fails. This is caused by the project based variables being evaluated on the context of the active project not the specified project in the debug configuration. Using variables with a workspace context work correctly. |
IDE-9032 |
"Rename & Import Existing C/C++ Project into Workspace" option allows the use of illegal characters in the new project name |
Project Generation Core |
Rename and Import existing C/C++ project does not have the same restrictions as new project wizard. |
IDE-8980 |
Headless Build error with Synergy project |
Renesas Synergy |
When using the eclipsec.exe tool and running headless builds it is possible to see an error created as seen below: A message box is displayed that states “An error has occurred. See the log file .log” This is due to the eclipsec.exe not picking up the correct Java version. To work around this issue please copy eclipse.ini to eclipsec.ini and execute the headless build again. |
IDE-8875 |
GDB Server will crash when Start address is larger than End address in Find/Replace/Fill Memory dialog |
Memory View plugin |
e2 studio can crash when the memory view Find/Replace/Fill feature has a start address larger than the end address. |
IDE-8795 |
Breakpoint filter is not restored when reconnecting debugger |
Debugging RX |
If you perform Disconnect-> Connect operation on the debugger, the Breakpoint Filter setting will not be restored correctly. In the above operation, check the Breakpoint Filter and reset it manually. |
IDE-8726 |
Exception was thrown when specify synergy license file by place-holder |
Renesas Synergy |
When using a placeholder in the Synergy license dialog it throws an exception. Please use a full path to the file. |
IDE-8711 |
Timing to show 'Unable to modify eventpoints' message is strange. |
Application |
When the timer start/stop events are set in Editor view of RX, the message to notify the limit number may not be displayed. |
IDE-8651 |
Not possible to update e2 studio |
Application |
If during the update process you see a message similar to: "Backup of file c:\renesas\e2studio\eclipse\e2studio.exe failed. File that was copied to backup could not be deleted: c:\renesas\e2studio\eclipse\e2studio.exe" Then this can be avoided by renaming the e2studio.exe executable after the check for updates process has started. |
IDE-8627 |
System Explorer launch breaking E2 |
Application |
On some systems you may encounter an error when launching the system explorer from the Project Explorer context menu. If using this causes e2 studio to freeze or context menus to stop displaying you should terminate the e2 studio process. |
IDE-8579 |
Execution time for the last function may not be displayed in Profile View. |
GDB server RX |
In Profile view, execution time for each function is calculated for the function which is returned out. If the execution stopped at the middle of the function, execution time of the function may not be added. |
IDE-8555 |
Unable to create a synergy project in Turkish Windows 8.1 |
Project Generation Core |
When using Turkish Windows with Synergy you may experience problems creating a project. Please use English language settings for your host OS and re-try if you experience this. |
IDE-8461 |
NO TRACE ON S3A7 |
GDB Server Synergy |
On Synergy S3-based devices the trace can sometimes fail with 0 records. |
IDE-8450 |
Empty view on minimize and restore (Variables, Expression, IO Register, etc) |
Application |
When minimizing a view such as Expressions, Registers or IO Registers and the restoring the view it can appear blank. If this happens repeat the operation and the view contents will be visible again. |
IDE-8438 |
'Internal Flash Memory Overwrite' option for RX E1 needs the number limitation. |
Debug Configuration |
If more than 16 non-adjacent items are selected from the "Internal Flash Memory Overwrite" dialog, only the first items will be valid. Others will be discarded. |
IDE-8303 |
An internal error for “Acquiring Profile Result” may be shown when the program stops/starts |
Profile plugin |
An internal error for "Acquiring Profile Result" may be shown when the program stops/starts |
IDE-8302 |
Semihosting - printf causes subsequent file operations to fail |
GDB server |
When using semihosting, having a printf command before file io operations causes them to fail. Scenario best explained through sample code. Create a synergy Blinky project in hal_entry.c at the top of the file include the following line: #include "stdio.h" //inside void hal_entry(void) try the following samle code: ///------------------------SAMPLE CODE-------------------------- initialise_monitor_handles(); printf("Hello\n"); FILE * pFile; char c; pFile=fopen("c:\\alphabet.txt","wt"); for (c = 'A' ; c <= 'Z' ; c++) { putc (c , pFile); } fclose (pFile); //-----------------------END SAMPLE CODE--------------------- // Before fix, the Renesas Debug Virtual Console has the following output Hello // There was no file c:\\alphabet.txt //After fix the Renesas Debug Virtual Console has the following output Hello // There should also be a file c:\\alphabet.txt created, with the following output: ABCDEFGHIJKLMNOPQRSTUVWXYZ |
IDE-8165 |
The stack size of GCC-RL is incorrect for a few devices |
Target Information Tool |
For the devices: DR7F0C8066 DR7F0C8076 DR7F0C8086 DR7F0C8096 The stack size should be 0x64 but is in fact 0x32. You can modify this in the linker sections after the project is created. |
IDE-8099 |
Cursor hovering over the breakpoint Types causes e2 studio to crash |
Application |
When using Ubuntu using Unity there is an issue which causes e2 studio to crash. When hovering over the breakpoint types the e2 studio application crashes. Caused by Ubuntu/Eclipse issue, see Eclipse Bug 419729. Workaround is given but cannot be added to product automatically. |
IDE-7524 |
RZ/T1 Reload doesn't work on RAM_BOOT project |
GDB Server RZ |
For RAM based RZ-T1 projects a redownload of code will trigger a reset that erases the RAM making further debugger operation impossible. The workaround is to instead disconnect and then reconnect. |
IDE-7508 |
CCRX: Warning dialog shows many times on Turkish OS when input 'i' key for e2 studio location |
Installer |
Problem: An error occurs by project operation when a non-ASCII character was used for the file name or the folder name. Workarounds: Please don't use non-ASCII characters for the file name or the folder name. |
IDE-7498 |
Multi-byte chars should be denied as Build-Debug configuration name |
Application |
Multi-byte characters can cause a compilation failure when used as a build configuration name in e2 studio. Therefore, multi-byte characters should NOT be applied to debug/build configuration names. Note: This issue affect both for configuration management dialog and the configuration creation dialog of Optimization Assistant. |
IDE-7423 |
Disassembly view does not always update on initial opening |
CDT |
In some cases, the disassembly view does not refresh correctly on suspend. When this problem happens refreshing the disassembly view does not fix the problem. To restore the functionality close and re-open the view. |
IDE-7419 |
RL78 on-chip debugging and reserved areas problem |
Application |
In older versions of e2 studio the RL78 debugger would protect OCD memory areas for the E1 emulator. However in some cases this would cause issues. This is no longer done and GCC projects will work well. If you are using IAR projects this may cause some problems for your debugging. A new GDB monitor command has been added to protect/overwrite memory. This will allow the same behavior as e2 studio 3.x. e.g. monitor protect_memory, fef00, 100, ff Any attempt to write to address 0xfef00 to 0xfefff will cause 0xff to be written instead. A warning message will be shown in the GDB server console window. This can be added to the initialization commands within the debug configuration for the RL78 E1 emulator. |
IDE-7412 |
Setting RL78 register fails |
GDB server RL78 |
When using RL78 the HL register value cannot be modified in some circumstances. This will only occur when bank 0 is not selected. Changing HL value only ever causes Bank 0 HL to change. View will always show current bank value. Values not in bank 0 can still be changed by accessing bank registers directly. |
IDE-7403 |
Indexer setting not saved. |
CDT |
The setting 'Use a fixed build configuration' in the dialog, Properties->C/C++ General->Indexer is not saved when the user checks it. This can be caused by visiting the properties, modifying the indexer setting and then visiting settings. If you do not visit settings the option is stored correctly. |
IDE-7277 |
[IAR][RL78] Linker extra options were not imported |
IAR plugins |
In some cases the IAR project importer does not perfectly import all set build options. One example is the -HFF command line option that can be specified in the command line options text box for the linker. |
IDE-6616 |
Data Access Event Break compare value always converted to hex |
Eventpoints plugin |
When adding a new Data Access eventpoint, the Compare value (on the Data Access Settings tab) is always converted to hex and subsequently displayed in hex even if the value entered does not include an 0x prefix. |
IDE-6605 |
Eventpoints disabled when e2 studio first opened. |
Eventpoints plugin |
The enable state of eventpoints for any debug configuration is not restored when the debug configuration is launched for the first time after e2 studio is started. In subsequent launches the eventpoints are enabled/disabled appropriately. |
IDE-6529 |
Disassembly view is empty after restart |
CDT |
After restart on occasion the disassembly window can be empty. Refreshing the window or stepping works around the problem. |
IDE-6408 |
(RX) Selecting user boot mode always show the message. |
Debug Configuration |
When User boot mode is selected at the setting for Mode pin in CPU Operating Mode, the warning for USB boot program is displayed even if the device does not have USB boot program. Please click 'yes' if the device does not have USB boot program. |
IDE-6350 |
[Multiple Configuration]: NullPointerException with custom configuration |
CDT |
NullPointerException is observed when adding a custom configuration and selecting the same configuration within the ‘Multiple Configuration…' selection at the same time. This issue only occurs if user has not applied after creating new config: https://bugs.eclipse.org/bugs/show_bug.cgi?id=352047 |
IDE-5897 |
Build error when project path has Chinese/Japanese text. |
Managed Build |
When operating e2 studio in a path that has Chinese or Japanese in the path names you may experience problems invoking the application. Please rename the directory with alphanumeric characters. You may also experience issues with building when folder names have Japanese or Chinese characters. This can be avoided in the same manner. |
IDE-5780 |
rh850 BPC events do not count in the status area of the eventpoints view |
GDB Server RH850 |
The counter of the event points in Eventpoint view will not be counted correctly. |
IDE-5770 |
Memory View for RX Little Endian shows IO endian reversed |
GDB server RX |
RX targets and IO registers greater than 1 byte. e.g. winA 0x88028 winB 0x8802a View register in both IO view and register view. Value in memory view is reversed. This is because the IO, ( like all RX memory for little endian targets is reversed). |
IDE-5637 |
(RH850) Disassembly result of PE1 is different from the result of PE2. |
Multicore Debugging RH850 |
For RH850 multicore devices, disassembly result may be different from the expected. In this case, please refresh the view after changing the debug context to the other PE. |
IDE-5547 |
Trace record event for READ access with compared data acquires information which does not match it. |
GDB Server RH850 |
To use the data access events as trace start, trace stop or trace record for RH850 with E1 emulator, please do not use the "Compare Settings" condition for the event. |
IDE-4982 |
[RX] The debugger works same as 'Equals' even if I select 'Not Equals' in 'Comparison:' of 'Data Access Settings'. (only when 0x0 is specified to Mask Value) |
GDB server RX |
When a data access event for RX is set with the data mask value as 0, the comparison will be treated as "Equals" and the data mask value will be treated as 0xFFFFFFFF. |
IDE-4876 |
Rx, In flash write mode, debugger features should be disabled |
Debug Configuration |
When debugging with RX, if the settings are in flash write mode, the debugger features are not available. If the ID code is changed or the communication I/F is FINE, reading memory will fail after download finished. Please disconnect from emulator and pull USB cable out in this case. |
IDE-4607 |
[BREAKPOINT] (RL78)Behavior in the case of the error by Add Watchpoint. |
GDB server |
When sub menu "Add Watchpoint" is performed from a Memory view, it seems to have been registered correctly in the Breakpoints view even if there is an error condition. An error occurs by "Add Watchpoint", when the maximum number of events was exceeded, or when a ROM area is specified. |
IDE-4492 |
The Module View of e2studio does not display any information when an executable which includes debug information was downloaded to the target. |
Application |
The Module View of e2 studio does not display any information when an executable which includes debug information was downloaded to the target. |
IDE-3950 |
breakpoints cannot be unset within the editor when code is #ifdef out |
Application |
Breakpoints cannot be unset on editor if the codes are out of #ifdef close. Those breakpoints can be removed in Breakpoints View. |
IDE-3389 |
Source Addresses: multiple debug contexts with same-named source file |
Application |
When debugging files with the same name show source addresses even though it may not be correct for the file in question. The full file path is not considered just the filename and current debug context. This can lead to e2 studio showing addresses unnecessarily. |
IDE-2716 |
BeforePC events on IECube temporarily hardcoded limit of 4 |
GDB server RL78 |
Before PC events on IECube temporarily hard coded limit of 4. |
IDE-2246 |
The RX simulator does not allow trigger count on data access events. |
Eventpoints plugin |
The trigger count for data access event for RX simulator will be ignored. |
IDE-1778 |
More than 4 'Internal Flash Memory Overwrite' blocks are allowed |
Debug Configuration |
When setting the 'Internal Flash Memory Overwrite' debug option, it is possible to exceed the maximum number of non-continuous memory blocks supported. No warning is given if this limit is exceeded. When setting this option ensure the limit (16 for RX devices) is not exceeded. |
IDE-1616 |
The options of a Build Configuration were not correct after specifying “Multiple Configurations...” functionality. |
Managed Build |
The options of a Build Configuration were not correct after specifying Multiple Configurations... functionality. |
IDE-874 |
[BREAKPOINT ISSUE]: Execution Address Eventpoints with trigger count do not work with Breakpoints on Segger RX |
GDB server RX |
Execution Address Eventpoints with trigger count do not work with Breakpoints on Segger RX. Setting an execution address eventpoint with a trigger count on Segger JLink RX62N is not possible if any breakpoints exist, including the default at main. If an execution address eventpoint with a trigger count is set with a breakpoint both the eventpoint & the breakpoint do not function. Multiple breakpoints are set then only 1 does not work. Additional eventpoints function as normal. |
Fixed Issues Requiring Inclusion in Release Note:
Key |
Summary |
Component |
Description |
IDE-35687 |
Assign register name parser for RE devices |
Smart Manual plugin |
With project of RE device, information from Smart Manual database will not be shown when search in Smart Manual view or hover on register/bit in Code Editor. |
IDE-35080 |
Build project failed after using "Renesas CCRX project conversion to Renesas GCC RX" |
CCRX to GCC Converter |
When creating a default CCRX project created in the latest e2 studio and importing this using the CCRX to GCC RX conversion and building results in a build failure. |
IDE-34907 |
[RL78] Startup breakpoint and source code breakpoint at same address. Does not break. |
GDB server RL78 |
The program will fail to break if the startup break option is selected (eg at main) and then a breakpoint (software or hardware breakpoint) is added manually at the same line. |
IDE-34727 |
E2 - Startup breakpoint and source code breakpoint at same address. Does not break. |
GDB Server E2 ARM |
The program will fail to break if the startup break option is selected (eg at main) and then a breakpoint (software or hardware breakpoint) is added manually at the same line. |
IDE-34424 |
Program does not stop at Reset_Handler after changing Optimization level of RA project |
Debugging RA Linux |
The download of programs to RA family targets under Linux host environments is not working. Therefore, new programs or settings changes will not be reflected in the target memory. |
IDE-34236 |
Cannot install e2 studio 2020-04 if no internet connection |
Installer |
e2 studio failed to install when there is no internet connection. |
IDE-34063 |
Changing breakpoint type doesn't work at first try |
Application |
After invocation of e2 studio |
IDE-33887 |
Memory view: Fill and Replace function does not work correctly |
CDT |
None |
IDE-33767 |
J-Link V6.64 Warning with RA Platform Installer v7.8.0 |
GDB Server RA |
A J-Link warning message will appear if a software breakpoint is added at the same point as an existing hardware breakpoint. This usually happens if the start-up break option is selected (e.g. at main) and then a software breakpoint added manually at the same line. Also, if a hardware breakpoint is added at the same line then the target program will fail to break without a warning message. |
IDE-33753 |
Path for optimized library missing for CPP projects |
ARM GCC Plugins |
When creating an RZ CPP project and selecting "Optimized" for Library Generator, the path to optlibinc folder is missing from Compiler's Includes paths. As a workaround, the path can be manually added. |
IDE-33663 |
[RX SC] Pin enabled status works incorrectly in e2studio 64bit env |
Smart Configurator |
The filter box in the Pins tab of the Smart Configurator editor may cause the checkboxes in the Pin Function table to be displayed incorrectly. If the checkboxes of the filtered results are not correct, please undo the filterbox search term and click on the "Enable" column header to re-sort the checkboxes. Note: This issue occurs only in e2 studio 2020-04. |
IDE-33578 |
Data Access Event: Disable data access size when not using data comparison (E2 - ARM) |
Eventpoints plugin |
When debugging RA devices, data access event without data comparison will detect all access of BYTE/WORD/LONG, even if access size is specified. This behavior is a specification. In case of using E2/E2LITE, the access size will be ignored. In case of using J-Link, please specify BYTE for the access size manually. |
IDE-33402 |
Can not set a breakpoint with RE debugger. |
Application |
In some situations, after startup the default breakpoint type reverts to "C/C++ Breakpoint" rather than "e2 studio Breakpoint". If this is the case then you can change back to the"e2 studio Breakpoint" type by right clicking on the breakpoint, editor column. Then selecting "Breakpoint type" from the context menu and then selecting "e2 studio Beakpoint". Leaving as C/C++ Breakpoint will mean limited access to hardware breakpoint functionality. |
IDE-33394 |
Tool Chain Editor "Toolchain" should be labelled correctly |
Renesas RE |
When using the RE device family you may notice that in the project settings > C/C++ Build > Tool Chain Editor, the "Current toolchain" combo has an item labelled "Toolchain". This refers to the toolchain "GCC for Renesas RE". |
IDE-33387 |
[Current consumption] Tooltip of loaded data in chart legend show incorrect information |
Current Consumption View |
When hovering on the loaded chart name in Current Consumption view to see its information, "Average current" and "Maximum current" always show value 0 (uA). This information is not displayed correctly. |
IDE-33322 |
Handle the case that data access event with comparison over of maximum. |
Eventpoints plugin |
When debugging RA family with E2/E2 Lite emulator, some device can specify data comparison condition in Eventpoint view. As the data comparison event will consume 2 events, if the rest of events are less than 2, setting the data comparison event will fail. In this case, the event will be displayed with the error icon, but the check box of it will be checked. Please uncheck it manually. |
IDE-33235 |
Eventpoint can still add Trace start/stop event when exceeding maximum events |
Eventpoints plugin |
Currently, when using E2 ARM, the count of Eventpoints may not correct. Please inspect the icons next to Eventpoints before using them. If there are error/warning icons after setting events, that means events do not set on target. Please recheck the Eventpoints that have the error icon. If address is valid, it means number of events exceeds the limit. |
IDE-32710 |
On Renesas RL78/G14 peripheral simulator, the problem when using timer RD to control the event count period in event count mode of timer RJ |
Device Support RL78 |
[On Renesas RL78/G14 peripheral simulator, the problem when using Timer RD for controlling the event count period for Timer RJ in event counter mode] When using timer RJ in event counter mode, if the settings of the related registers meet the following (1) to (3), the simulator operates differently from device specifications. (1) Timer RJ mode register 0 (TRJMR0) Timer RJ operating mode selection: Event counter mode (2) Timer RJ I/O control register 0 (TRJIOC0) TRJIO count control: Event is counted during polarity period (high-level period or low-level period) specified for timer output signal (3) Timer RJ event pin select register 0 (TRJISR0) Timer output signal selection: “TRDIOD1” or “TRDIOC1” to select timer RD [Simulator’s operations that differ from device specifications] - When “an event is counted during the high-level period” is selected as polarity selection, the TRJ0 counter does not count, even if the output signal of timer RD is in the high-level period. - When “an event is counted during the low-level period” is selected as polarity selection, the TRJ0 counter counts, even if the output signal of timer RD is in the high-level period. [Workaround] There is no workaround. |
IDE-32455 |
2020-04 1st startup after installation slow if Smart Configurator or RTOS Download installed |
Application |
When running 2020-04 for the first time the application can be very slow when the Smart Configurator feature is for any device family installed. The application will appear to hang for 2-3 minutes. Please wait and the application will recover. Note this only happens on the very first start-up. |
IDE-32122 |
Eventpoint view cannot count hardware breakpoint at main |
Eventpoints plugin |
When using the RE device the maximum number of breakpoints that can be set does not count the automatic breakpoint set at main. This can then cause a connection failure as this breakpoint cannot be set and the sequence fails. Removing one user breakpoint will allow the connection to complete successfully. |
IDE-31257 |
Break point at main may not work if hot plug is enabled in other target. |
Debug Configuration |
Break point at main may not work if hot plug is enabled in other targets. To make break point at main working, please disable hot plug in other targets. |
IDE-30328 |
Update GetDeviceInfo for supporting the IAR v4 toolchain definitions |
Application |
The latest version of the IAR EW build support is now supported inside e2 studio. This will enable the code generator to be used for v4 IAR EW based projects. |
IDE-29829 |
Failed breakpoint looks to be set correctly after reload. |
Source Line Address Column |
When setting break point failed after download is invoked manually, the status of the break point may not be displayed. In this case, the break point will not work. |
IDE-29564 |
Memory view doesn't recover the display from '??'. |
Memory View plugin |
When updating memory view while the program is running and reading memory failed, memory view may show '??' as value. In this case, please close the view and reopen it after suspended. |
IDE-28351 |
[Current Consumption] Even Monitor point is deleted, its information still be shown in Acquisition setting |
Current Consumption View |
Even if monitor points have been deleted, their information is still shown in acquisition setting dialog. Please re-check whether monitor points are available before setting. |
IDE-27986 |
customer issues with long clean command |
ARM GCC Plugins |
e2 studio when executing the clean command as part of the build process will sometimes fail. This is because the command line length limit is reached. It can occur when cleaning a huge number of files or using deep nested directories. In this case please delete the files manually. This will avoid the issue. |
IDE-34242 |
Move "Renesas" Preferences category from under C/C++ to root |
Application |
The Renesas preferences location has changed from under C/C++ category to the root of Preferences. |
IDE-33753 |
Path for optimized library missing for CPP projects |
ARM GCC Plugins |
When creating an RZ CPP project and selecting "Optimized" for Library Generator, the path to optlibinc folder is missing from Compiler's Includes paths. As a workaround, the path can be manually added. |
IDE-33068 |
Update RL78 device file in e2 studio 2020-07 |
Device Support RL78 |
When you use the RL78/G1M or RL78/G1N, select 5.0V as the voltage supplied from the emulator. And, do not select "Yes" in the "Low-voltage OCD board" field on the "Connection Settings" tab of the "Debug Configurations" dialog box. |
IDE-32750 |
Modify RZ/A2M Flash memory UI : Hyper Bus & Hyper Flash Memory |
Debug Configuration RZ |
Selecting the combination of HyperBus bus type and HyperFlash memory type is not currently supported by the underlying debug architecture. In these scenarios you should only select Debug Configuration > Debugger > Debug Tool Settings > Flash > Flash Memory Type as SerialBus and Flash Memory Type as SerialFlash. |
IDE-32455 |
2020-04 1st startup after installation slow if Smart Configurator or RTOS Download installed |
Application |
When running 2020-04 for the first time the application can be very slow when the Smart Configurator feature is for any device family installed. The application will appear to hang for 2-3 minutes. Please wait and the application will recover. Note this only happens on the very first start-up. |